Tip #204: Comparing UV Spectra from Different Channels in a Report, at Various Retention Times

Tip #204: Comparing UV Spectra from Different Channels in a Report, at Various Retention Times

In this tip, I will show you how to report spectra from different 3D PDA channels which are extracted at various retention times.

The way to accomplish this goal is to build a library of UV spectra and then report the library (Refer to Tip 144, Creating a UV Library).

STEP 1

STEP 1

Right click on the ‘Channels’ of data and select ‘Review’.

STEP 2

STEP 2

Extract a chromatogram and either manually integrate the peaks of interest or use a processing method. From the ‘Spectrum Review’ menu, select ‘Keep Spectra When Switching Channels’.

STEP 3

STEP 3

Go to the next ‘3D channel’, extract a chromatogram and integrate the peaks.

STEP 4

STEP 4

From the ‘Library’ menu, select ‘New Library’. Enter a name for the library and click ‘Create’.

STEP 5

STEP 5

To add the spectra to the library, go to the ‘Library’ menu, select ‘Add to Library (library name)’.

STEP 6

STEP 6

In the ‘Add Spectrum to Library’ dialogue, enter a name and description and click ‘OK’. Repeat for all spectra and click ‘OK’.

Now that we have a library, let’s build the Report Method.

STEP 7

STEP 7

Go to the ‘Methods’ tab, right click and select ‘New Method’ > ‘Reporting Method’.

STEP 8

STEP 8

When Report Publisher opens, cancel the ‘New Method/Group’ dialogue.

STEP 9

STEP 9

Expand ‘PDA/MS Groups’, expand ‘Spectral/Library Plots’ and double click on ‘Library Plot Group’.

STEP 10

STEP 10

Open ‘Configuration Manager’, select ‘Libraries’ and size the window so it is on top of the ‘Report Publisher’. Click and drag the library from ‘Configuration Manager’ into the ‘Report Publisher’.

STEP 11

STEP 11

When the ‘Open Report Method’ dialogue opens, select the last choice/option and click ‘OK’.

STEP 12

STEP 12

Close Preview. Right-click on the spectral plot and select ‘Spectral Plot Properties’.

STEP 13

STEP 13

On the ‘Spectra’ tab, adjust the UV labels.

STEP 14

STEP 14

On the ‘Legend’ tab, expand UV Spectra and double click ‘Name’.

STEP 15

STEP 15

The result is an overlay of the spectra with a legend under the plot.

It’s that easy!

Final Notes

You can use either the Pro or QuickStart interface for this tip.


About the Author

About the Author
Neil Lander

Neil Lander

Neil provides internal support for Empower CDS software and is focused on developing laboratory software solutions that help organizations achieve their scientific and operational objectives.