waters_connect 3.7.0 Release Overview

waters_connect 3.7.0 Release Overview

Introduction

Introduction

This page provides an overview of the waters_connect 3.7.0 release, compatible waters_connect applications, instrument drivers and supported system configurations including liquid chromatography modules, mass spectrometry instruments, and detectors. For more information on waters_connect release types and associated level of software support please visit waters_connect Releases Overview.

Release Overview

Recommended Use

waters_connect helps you accelerate the time to outcomes with workflow solutions ranging from quantitative, biopharma, and accurate mass-based analyses helping you reach new levels of efficiency, precision, and confidence.

Key Solutions Available with this Release

  • waters_connect for Quantitation — Quantitative analysis software available on our core Xevo tandem quadrupole family of mass spectrometers to enable laboratories to process large sample batches quickly and easily, significantly reducing the time spent on data review. Maximize your productivity with a compliant-enabled workflow for analytical methodologies ranging from PFAS to genotoxic impurity analysis.
  • waters_connect for Biopharma — Accurate mass applications for protein-based therapeutics, vaccines, and nucleic acid-based therapeutics including applications for bioprocessing (spent cell culture media) and product quality attribute monitoring.
  • waters_connect for Small Molecules — Accurate mass-based solutions for screening of small molecules with versatile qualitative and quantitative analysis of compounds like pesticides, drugs of abuse, metabolites, impurities, extractables, and leachables.
  • waters_connect for Research & Routine — Accurate mass-based metabolomics, lipidomics and metabolite identification solutions with integration with 3rd Party software (via .mzML and/or via API).

Key Benefits

Key Benefits

Base Kit

Base Kit

waters_connect Base Kit comprises of platform Services, utility tools and core applications such as Hub, Administration, Scientific Library for general system use.

Key benefits in this kit include:

  • Enhanced compliance readiness through improved administrative access controls using global policies and role definitions, including:

    • Ensuring consistent date and time stamps across all applications via a new date and time policy;
    • Differentiating between Customer and Waters Administration roles;
    • Password-controlled mechanism for resetting administrator accounts;
  • Increased compliance readiness with more comprehensive insights in the audit trail including:
    • extended traceability for records associated to the raw data set;
    • view simple or detailed history of records , including the ability to restore previous versions;
    • controlled generation of analysis copies within the MS Quan application;
    • full audit trail and control for user and system actions during data acquisitions;
    • Record of key actions within the application, such as tracking the number of times re-processing is performed.
    • Quick and easy access to targeted system audit trail information, reducing time spent on administrative tasks.
    • Rich information on imported data records, including “created date,” “last update date,” “created by,” “last updated by,” “restore date,” and “restored by” fields.
  • Increased compliance readiness with more efficient records handling in draft states and better control policies over signature methods and active multi-user sessions, such as:
    • new global policies to control and record actions in the audit trail when closing records in a draft state, whether discarding or saving changes;
    • view read-only records generated by other users in edit state, with the option to take ownership of those records in draft state.
  • Enhanced compliance readiness through a richer reporting and e-signature workflow, including:

    • Displaying the electronic signature status directly within waters_connect application reports;
    • Permission-controlled editing and customization of application reports and definition of e-signature sequences;
    • clear and traceable history of records for generated reports, linked to report templates and analyses.
  • Improved awareness of storage space capacity for efficient product use and performance with a standalone tool that allows viewing of space usage across all waters_connect install types.
  • Reduced product installation times for clean waters_connect workstation installs within an automated software deployment mechanism that chains the installation of core services, applications, and instrument drivers.

Acquisition Kit

Acquisition Kit

waters_connect Acquisition Kit comprises of Sample Submission, Method Editor and Laboratory Network Device applications. This kit enables data acquisition with Waters instrument systems used with waters_connect Quantitative analysis software, such as Xevo TQ-S cronos, Xevo TQ-S micro, Xevo TQ-XS and Xevo TQ Absolute, and/or accurate mass applications with Xevo G2-XS QTof, Xevo G3 QTof, Xevo MRT, BioAccord LC-MS System and ACQUITY RDa detector.

Key benefits in this kit include:

  • Improved productivity when submitting samples with Xevo Tandem Quadrupole instruments by enabling a fast polarity switch of 4 ms in the method editor application.

Data Interrogation

Data Interrogation

waters_connect LC-MS Toolkit enables data interrogation outside of the defined workflows and provides flexibility to the software that is needed for more advanced use.

Key benefits in this application include:

  • Increased data clarity and speed to results with data view and interrogation enhancements in the LC-MS Toolkit application, such as:
    • automatic calculation and annotation for the mass resolution of an ion;
    • base peak mass annotations in chromatograms;
    • view and interrogate Xevo MRT data;
    • perform multiple extracted ion chromatograms from pre-saved groups of analytes;
  • Increased productivity by generating LC-MS Toolkit sessions in real time and post acquisition at the sample list level from within the submission application.

Data Conversion

Data Conversion

waters_connect Data Convert enables increased data compatibility with third-party software applications via conversion of MS, MS/MS, DDA and MSE data into .mzML format.

Key benefits in this application include:

  • Improved productivity when submitting samples with Xevo MRT, Xevo G3 QTof, Xevo G2-XS QTof and ACQUITY RDa by converting acquired data to generic file format (.mzML) in real-time, ensuring immediate availability for third-party software use

MS Quan

MS Quan

waters_connect MS Quan is a quantitative analysis software available on our core Xevo tandem quadrupole family of mass spectrometers. It enables routine small-molecule quantitation and accelerates quantitation data processing and review steps with exception-focused review and easy-to-view chromatogram windows for multiple samples.

Key benefits in this application include:

Expanding MS Quan application capabilities with focus on impurity processing & customer feedback, including:

  • Optical data processing (TUV & PDA)
  • Recovery calculations
  • Relative standard error
  • Lock data on signing reports
  • Per injection reports including overlays
  • Simple exceptions in report tables

UNIFI

UNIFI

waters_connect UNIFI enables the execution of accurate mass experiments ranging from Small Molecules to Biologics. Moreover, it provides access to core applications such as System Console, Device Management, Explorer, and Qualification for general system use.

Key benefits in this application include:

  • Quality improvements and critical anomaly resolution

Peptide MAM

Peptide MAM

waters_connect Peptide Multi-Attribute Method (MAM) enables monitoring of biopharmaceutical product quality attributes (PQA) at the peptide level.

Versions released

waters_connect 3.7 is compatible with Peptide MAM 1.8.2

Benefits

Key Benefits in Peptide MAM 1.8.2 include:

  • General maintenance release

  • Defect fixes

Intact Mass

Intact Mass

waters_connect Intact Mass enables biologics mass confirmation and purity determination of oligonucleotides, peptides, protein and conjugates.

Versions released

waters_connect 3.7 is compatible with Intact Mass 1.9.

Benefits

Key Benefits in this application include:

  • Automated Calculations of DAR and Drug Distribution for Conjugated Molecule Analysis - Users can now deploy a BioAccord System, Xevo G3 QTof, or Xevo MRT QTof to analyze conjugated molecules, specifying the conjugate and its mass in the INTACT Mass data processing parameters, and have the calculation of Drug Antibody Ratio and distribution of conjugate forms automatically performed from the acquired data.

  • Controls for manual adjustments of chromatographic integration - Users can now manually adjust chromatographic peak integration and associated peak identification results and use those reintegrated peaks to direct the processing of mass spectral data.

  • Sample List Entry of Chemical Formula - User can now specify a ‘Chemical formula for deconvolution’ that will be used to refine the deconvolution isotope model, improving deconvolution mass accuracy and quantification.

  • Updated Sample List Column ‘Expected Masses’ changed to ‘Expected Masses and/or Chemical Formulas’: Users now can enter targets as numeric masses, as chemical formulas, or a mixture of both.

  • New Method option within ‘Specify calculation parameters’, allowing the user more control over the ‘Main Peak Retention Time Window’ to improve main peak identification in Optical Only and Variant Analysis workflows

  • Bioprocessing workflow: Additional sample list columns for Time Point and Dilution Factor that facilitates processing time series trending data (in bioprocess monitor or in third party solutions) and dilution factor to enable clearer results visualization and trending.

CONFIRM Sequence

CONFIRM Sequence

waters_connect CONFIRM Sequence enables streamlined oligonucleotide sequence confirmation and impurity characterization workflow.

Key benefits in this application include:

  • The user can now confirm if their chosen nucleic acid digestion strategies can theoretically produce the desired sequence coverage, using a visualization of theoretical digest sequence coverage, including calling out segments of isobaric mass ambiguity. This helps users to determine the best digestion strategy to achieve optimal sequence coverage using unique digestion products;

  • Localization into Japanese.

Map Sequence

Map Sequence

waters_connect Map Sequenceenables accurate mass mapping of digested oligonucleotides.

Key benefits in this application include:

  • Input of in silico predicted digestion products
  • Processing of pre-acquired data to identify digestion products
  • Grouped results for rapid assessment of sequence coverage
  • Identification of structural isomers and sequence repeats
  • Output of results for coverage map review

     

Note: full information on new features and quality improvements available in the release notes

Applications

waters_connect for Quantitation

waters_connect for Quantitation

Quantitative analysis software available on our core Xevo tandem quadrupole family of mass spectrometers to enable laboratories to process large sample batches quickly and easily, significantly reducing the time spent on data review. Maximize your productivity with a compliant-ready workflow for analytical methodologies ranging from PFAS to genotoxic impurity analysis.

Acquisition

  • Sample Submission 2.5.0 [new] 
  • Acquisition Method Editor 3.8.0
  • Acquisition Method Editor 3.9.0 [new]  
  • Laboratory Network Device 1.22.0 [new] 
  • Cloud Edge sw for System Monitoring 4.15

Data View & Processing

  • LC-MS Toolkit 1.15.0
  • MS Quan 2.0.0
  • MS Quan 2.1.0 [new]

Instrument Drivers

  • ACQUITY UPLC DP 3.7.0
  • Xevo TQ-S cronos 1.7.0 [new] 
  • Xevo TQ-S micro 1.7.0 [new] 
  • Xevo TQ-XS 1.7.0 [new] 
  • Xevo TQ Absolute 1.7.0 [new] 

waters_connect for Biopharma

waters_connect for Biopharma

Biopharmaceutical accurate mass applications for protein-based therapeutics, vaccines, and nucleic acid-based therapeutics.

Acquisition

  • Sample Submission 2.5.0 [new] or UNIFI 3.13.0 [new] 
  • Acquisition Method Editor 3.8.0
  • Acquisition Method Editor 3.9.0 [new]  
  • Laboratory Network Device 1.22.0 [new] 
  • Cloud Edge sw for System Monitoring 4.15

Data View & Processing

  • LC-MS Toolkit 1.15.0
  • Data Convert 2.3.0
  • UNIFI 3.13.0 [new]
  • MAP Sequence 1.0.0
  • Peptide MAM 1.8.2
  • Intact Mass 1.9.0
  • CONFIRM Sequence 1.4.0

Instrument Drivers

  • ACQUITY UPLC DP 3.7.0
  • BioAccord 3.4.0
  • Xevo G2-XS QTof 4.4.0
  • Xevo G3 QTof 1.3.0
  • Xevo MRT 1.1.0
  • Xevo MRT 1.2.0 [new]
  • Vion IMS QTof 4.3.0

waters_connect for Bioprocessing

waters_connect for Bioprocessing

Bioprocess accurate mass applications for process (spent cell culture media) and product quality attribute monitoring including the Bioprocess Walk-Up Solution.

Acquisition

  • Sample Submission 2.5.0 [new]
  • Acquisition Method Editor 3.8.0
  • Acquisition Method Editor 3.9.0 [new]  
  • Laboratory Network Device 1.22.0 [new] 
  • Cloud Edge sw for System Monitoring 4.15

Data View & Processing

  • LC-MS Toolkit 1.15.0
  • UNIFI 3.13.0 [new]
  • Peptide MAM 1.8.2
  • Intact Mass 1.9.0

Instrument Drivers

  • ACQUITY UPLC DP 3.7.0
  • BioAccord 3.4.0

waters_connect for Small Molecules

waters_connect for Small Molecules

Accurate mass-based solutions for screening of small molecules with versatile qualitative and quantitative analysis of compounds like pesticides, drugs of abuse, metabolites, impurities, extractables, and leachables.

Acquisition

  • Sample Submission 2.5.0 [new] or UNIFI 3.13.0 [new] 
  • Acquisition Method Editor 3.9.0 [new]  
  • Laboratory Network Device 1.22.0 [new] 
  • Cloud Edge sw for System Monitoring 4.15

Data View & Processing

  • LC-MS Toolkit 1.15.0
  • Data Convert 2.3.0 
  • UNIFI 3.13.0 [new]

Instrument Drivers

  • ACQUITY UPLC DP 3.7.0
  • ACQUITY RDa 3.4.0
  • Xevo G2-XS QTof 4.4.0
  • Xevo G3 QTof 1.3.0
  • Xevo MRT 1.1.0
  • Xevo MRT 1.2.0 [new]
  • Vion IMS QTof  4.3.0

waters_connect for Research & Routine

waters_connect for Research & Routine

Accurate mass-based metabolomics, lipidomics and metabolite identification solutions with integration with 3rd Party software (via .mzML and/or via API).

Acquisition

  • Sample Submission 2.5.0 [new]
  • Acquisition Method Editor 3.9.0 [new]
  • Laboratory Network Device 1.22.0 [new] 
  • Cloud Edge sw for System Monitoring 4.15

Data View & Processing

  • LC-MS Toolkit 1.15.0
  • Data Convert 2.3.0 
  • UNIFI 3.13.0 [new]

Instrument Drivers

  • ACQUITY UPLC DP 3.7.0
  • Xevo G2-XS QTof 4.4.0
  • Xevo G3 QTof 1.3.0
  • Xevo MRT 1.1.0
  • Xevo MRT 1.2.0 [new]

[new] = latest application release.

Configurations

This section provides an overview on supported operating systems, maximum number of instrument systems in a Network install and ACQUITY pumps, detectors, sample managers, column compartments available in waters_connect 3.7.0.

Operating System Support for Workstation Installs

Operating System Support for Workstation Installs

Operating System
Windows

Requirements

  • Windows Defender must be set to Off
  • OS language: English (US), Japanese (Japan)
  • Windows images provided with waters_connect PCs include Windows IoT Enterprise licensing which enables extended support on the operating system end of service over the standard edition. View more information on Windows releases.

Versions Supported
Workstation PC

  • Windows 10 Enterprise LTSC 2021 edition (version 21H2)
  • Windows 10 Enterprise IoT LTSC 2021 edition (version 21H2)
  • Windows 10 Pro version 22H2

Operating System Support for Network Installs

Operating System Support for Network Installs

Operating System
Windows

Requirements

  • Windows Defender must be set to Off (Server PCs)
  • OS language: English (US), Japanese (Japan)
    • Note: for Client PCs only the software deployment is supported on European and Japanese language versions of Windows. However, Hub is displayed in English (US) or Japanese (Japan) only.
  • Windows images provided with waters_connect PCs include Windows IoT Enterprise licensing which enables extended support on the operating system end of service over the standard edition. View more information on Windows releases.

Versions Supported

Server PC

  • Windows Server 2019 Standard

LND PC

  • Windows 10 Enterprise LTSC 2021 edition (version 21H2)
  • Windows 10 Enterprise IoT LTSC 2021 edition (version 21H2)
  • Windows 10 Pro version 22H2

Client PC

  • Windows 10 Enterprise LTSC 2021 edition (version 21H2)
  • Windows 10 Enterprise IoT LTSC 2021 edition (version 21H2)
  • Windows 10 Pro version 22H2

Mass spectrometry instruments supported on a single waters_connect network deployment

Mass spectrometry instruments supported on a single waters_connect network deployment

Instrument Type

Instrument Type

Instrument Type

Instrument Type

Instrument Type

Instrument Type

Instrument

Total Number of Systems

Recommended Number of Client PCs

Recommended Number of Users

Tof

Tof

Tof

Tof

Tof

Tof

  • ACQUITY RDa
  • BioAccord LCMS system 
  • Mix of Tof

up to 6

up to 6

  • up to 6 (concurrent)
  • up to 25 (active software accounts)

QTof

QTof

QTof

QTof

QTof

QTof

  • Xevo G2-XS QTof
  • Xevo G3 QTof
  • Vion IMS QTof
  • Mix of Tof and QTof
  • (Xevo MRT not supported)

up to 4

up to 4

  • up to 4 (concurrent)
  • up to 25 (active software accounts)

Tof & QTof

Tof & QTof

Tof & QTof

Tof & QTof

Tof & QTof

Tof & QTof

  • Mix of Tof and QTof
  • (Xevo MRT not supported)

up to 4

up to 4

  • up to 4 (concurrent)
  • up to 25 (active software accounts)

TQ

TQ

TQ

TQ

TQ

TQ

  • Xevo TQ-S cronos
  • Xevo TQ-S micro
  • Xevo TQ-XS 
  • Xevo TQ Absolute
  • Mix of Quads

up to 5

up to 5

  • up to 10 (concurrent)
  • up to 25 (active software accounts)

TQ, Tof, & QTof

TQ, Tof, & QTof

TQ, Tof, & QTof

TQ, Tof, & QTof

TQ, Tof, & QTof

TQ, Tof, & QTof

  • Mix of Quads
  • QTofs/Tofs

up to 6 in the following combos:

  • up to 3 TQ + up to 3 QTof

  • up to 4 TQ + up to 2 QTof

  • up to 3 TQ + up to 2 QTof + 1 Tof

  • up to 3 TQ + 1 QTof + 2 Tof

  • up to 3 TQ + up to 3 Tof

up to 6

  • up to 6 (concurrent)
  • up to 25 (active software accounts)

ACQUITY Instrument Systems (such as pumps, detectors, sample managers, column compartments) supported by waters_connect driver pack ACQUITY UPLC DP v3.7.0

ACQUITY Instrument Systems (such as pumps, detectors, sample managers, column compartments) supported by waters_connect driver pack ACQUITY UPLC DP v3.7.0

Note: ACQUITY modules firmware versions and more information are detailed in the ACQUITY UPLC drive pack release notes.


Microscale ACQUITY UPLC Systems

Microscale ACQUITY UPLC Systems

ACQUITY UPLC M-Class

ACQUITY UPLC M-Class

UPLC Configuration

  • uBinary Solvent Manager
  • uSample Manager-Fixed Loop
  • Auxillary Solvent Manager
  • Trap Valve Manager

Acquisition Apps

  • Sample Submission

Supported MS Instruments

  • Xevo MRT with NanoLockSpray and low-flow ESI probe
  • Xevo G3 QTof with NanoLockSpray and low-flow ESI probe
  • Xevo G2-XS QTof with low-flow ESI probe only

Analytical ACQUITY UPLC Systems

Analytical ACQUITY UPLC Systems

ACQUITY Premier/ACQUITY H-Class Binary Series (15,000 PSI limited systems)

ACQUITY Premier/ACQUITY H-Class Binary Series (15,000 PSI limited systems)

UPLC Configuration

  • Binary Solvent Manager (BSM)
  • Sample Manager - Flow Through Needle (SM-FTN)
  • Column Heater (CH-A)
  • Column Manager (CM-A/CM-Aux)
    • Note: with Sample Submission up to 2 CM-Aux units using 6 columns        

Acquisition Apps

  • Sample Submission (S)
  • UNIFI (U)

Supported MS Instruments

  • Xevo TQ-S cronos (S)
  • Xevo TQ-S micro (S) 
  • Xevo TQ-XS (S)
  • Xevo TQ Absolute (S)
  • BioAccord (S & U)
  • ACQUITY RDa (U)
  • Xevo G2-XS QTof (S & U)
  • Xevo G3 QTof (S & U)
  • Vion IMS QTof (U)
  • Xevo MRT (S)

ACQUITY Premier/ACQUITY H-Class Quaternary Series (15,000 PSI limited systems)

ACQUITY Premier/ACQUITY H-Class Quaternary Series (15,000 PSI limited systems)

UPLC Configuration

  • Quaternary Solvent Manager (QSM)
  • Sample Manager - Flow Through Needle (SM-FTN)
  • Column Heater (CH-A)
  • Column Manager (CM-A/CM-Aux) — Note: with sample Submission up to 2 CM-Aux units using 6 columns and Solvent Select Valve

Acquisition Apps

  • Sample Submission (S)
  • UNIFI (U)

Supported MS Instruments

  • Xevo TQ-S cronos (S)
  • Xevo TQ-S micro (S) 
  • Xevo TQ-XS (S)
  • Xevo TQ Absolute (S)
  • BioAccord (S & U)
  • ACQUITY RDa (U)
  • Xevo G2-XS QTof (S & U)
  • Xevo G3 QTof (S & U)
  • Vion IMS QTof (U)
  • Xevo MRT (S)

ACQUITY UPLC I-Class Plus Series (18,000 PSI limited systems)

ACQUITY UPLC I-Class Plus Series (18,000 PSI limited systems)

UPLC Configuration

  • Solvent Manager (BSM)
  • Sample Manager - Flow Through Needle (SM-FTN)
  • Sample Manager – Fixed Loop (SM-FL)
  • Column Heater (CH-A)
  • Column Manager (CM-A)

Acquisition Apps

  • Sample Submission (S)
  • UNIFI (U)

Supported MS Instruments

  • Xevo TQ-S cronos (S)
  • Xevo TQ-S micro (S) 
  • Xevo TQ-XS (S)
  • Xevo TQ Absolute (S)
  • BioAccord (S & U)
  • ACQUITY RDa (U)
  • Xevo G2-XS QTof (S & U)
  • Xevo G3 QTof (S & U)
  • Vion IMS QTof (U)
  • Xevo MRT (S)

ACQUITY UPLC Series (15,000 PSI limited systems)

ACQUITY UPLC Series (15,000 PSI limited systems)

UPLC Configuration

  • Binary Solvent Manager (BSM)
  • Sample Manager – Fixed Loop (SM-XY)
  • Column Heater HTCH
  • Column Manager CM/CHC

Acquisition Apps

  • UNIFI

Supported MS Instruments

  • ACQUITY RDa
  • Xevo G2-XS QTof

ACQUITY UPLC Tunable UV (TUV) Detector

ACQUITY UPLC Tunable UV (TUV) Detector

Acquisition Apps

  • Sample Submission (S)
  • UNIFI (U)

Supported MS Instruments

  • Xevo TQ-S cronos (S)
  • Xevo TQ-S micro (S) 
  • Xevo TQ-XS (S)
  • Xevo TQ Absolute (S)
  • BioAccord (S & U)
  • ACQUITY RDa (U)
  • Xevo G2-XS QTof (S & U)
  • Xevo G3 QTof (S & U)
  • Vion IMS QTof (U)
  • Xevo MRT (S)

ACQUITY UPLC Photodiode Array (PDA)/eLambda PDA Detector (1; 2)

ACQUITY UPLC Photodiode Array (PDA)/eLambda PDA Detector (1; 2)

Acquisition Apps

  • Sample Submission (S)
  • UNIFI (U)

Supported MS Instruments

  • Xevo TQ-S cronos (S)
  • Xevo TQ-S micro (S) 
  • Xevo TQ-XS (S)
  • Xevo TQ Absolute (S)
  • BioAccord (S & U)
  • ACQUITY RDa (U)
  • Xevo G2-XS QTof (S & U)
  • Xevo G3 QTof (S & U)
  • Vion IMS QTof (U)
  • Xevo MRT (S)

ACQUITY UPLC Fluorescence (FLR) Detector

ACQUITY UPLC Fluorescence (FLR) Detector

Acquisition Apps

  • UNIFI

Supported MS Instruments

  • BioAccord
  • ACQUITY RDa
  • Xevo G2-XS QTof
  • Xevo G3 QTof
  • Vion IMS QTof

ACQUITY Common Platform Sample Organizer (CPSO)

ACQUITY Common Platform Sample Organizer (CPSO)

Acquisition Apps

  • Sample Submission (S)
  • UNIFI (U)

Supported MS Instruments

  • Xevo TQ-S cronos (S)
  • Xevo TQ-S micro (S) 
  • Xevo TQ-XS (S)
  • Xevo TQ Absolute (S)
  • BioAccord (S & U)
  • ACQUITY RDa (U)
  • Xevo G2-XS QTof (S & U)
  • Xevo G3 QTof (S & U)
  • Vion IMS QTof (U)
  • Xevo MRT (S)

ACQUITY eSAT/IN Module

ACQUITY eSAT/IN Module

Acquisition Apps

  • UNIFI

Supported MS Instruments

  • BioAccord
  • ACQUITY RDa
  • Xevo G2-XS QTof
  • Xevo G3 QTof
  • Vion IMS QTof

Supporting Files

Torna all'inizio Torna all'inizio