waters_connect 4.5.0 Release Overview

waters_connect 4.5.0 Release Overview

Introduction

Introduction

This page provides an overview of the waters_connect 4.5.0 release, compatible waters_connect applications, instrument drivers and supported system configurations including liquid and gas chromatography modules, mass spectrometry instruments, and detectors. For more information on waters_connect release types and associated level of software support please visit waters_connect Releases Overview

Release Overview

Recommended Use

waters_connect Software helps you accelerate the time to outcomes with workflow solutions ranging from quantitative, biopharma, and accurate mass-based analyses helping you reach new levels of efficiency, precision, and confidence.

Key solutions available with this release are:

  • waters_connect for Quantitation | Quantitative analysis software available on our core Xevo tandem quadrupole family of mass spectrometers, enabling laboratories to process large sample batches quickly and easily, significantly reducing the time spent on data review. Maximize your productivity with a compliant-ready workflow for analytical methodologies ranging from PFAS to genotoxic impurity analysis.
  • waters_connect for Biopharma | Accurate mass applications for protein-based therapeutics, vaccines, and nucleic acid-based therapeutics including applications for bioprocessing (spent cell culture media and product titer) and product quality attribute monitoring.

  • waters_connect for Small Molecules | Accurate mass-based solutions for targeted and non-targeted screening of small molecules, offering versatile qualitative and quantitative analysis of compounds such as pesticides, drugs of abuse, metabolites, impurities, extractables and leachables, and identification of contaminants like polymers, PFAS, and PCBs in complex samples.

  • waters_connect for Data Readiness | Accurate mass-based metabolomics, lipidomics and metabolite identification solutions with integration with 3rd Party software (via .mzML and/or via API). Enabling multiomics research insights with confidence across discovery, quantitative, and translational applications with two key areas:   
    • Advanced acquisition modes
    • Versatile connectivity with 3rd party packages.
  • waters_connect for Charge Detection | Achieve precise mass measurement of challenging large and highly heterogeneous biologics up to 150 MDa including viral vectors, virus-like particles (VLPs), RNA, and protein complexes that were previously out of reach for mass characterization.

  • waters_connect for Imaging | Xevo MRT systems only: generate molecular spatial information directly from surfaces with Mass Spectrometry Imaging (MSI). The integration of DESI XS with Xevo MRT systems high spatial resolution, label-free molecular imaging directly from sample surfaces with minimal preparation, offering highly sensitive MS Imaging at speeds of up to 100 Hz, with sub-ppm mass accuracy, making it ideal for applications in biomedical research, drug distribution studies, and forensic analysis.

Key Benefits

Key Benefits

Base

Base

waters_connect Base offering comprises of platform Services, utility tools and core applications such as Hub, Administration, Scientific Library, Data view and Conversion for general system use.

Versions released

waters_connect 4.5.0 includes core services and applications such as Services 7.17.0, Hub 4.3.1, Administration 2.12.1, MS ToolKit 1.20.0, DataConvert 5.0.0

Benefits

Key benefits in Core

  • Increased Lab operational efficiency and reduced infrastructure cost of ownership for waters_connect Network with introduction of Infrastructure as a Service (IaaS)
  • Optimization of system administrator tasks with broader Data management and quality improvements in the Database Manager, including a more efficient backup methodology.

  • Compatibility with the most recent Network hardware options available on the market.

  • Automating workstation clean installs and upgrades with a utility tool that seamlessly looks after the software installation process.

  • Enabling a third-party application to connect to multi-instances of waters_connect workstation and/or network deployments.

  • Improved product quality and stability by addressing high impact software anomalies.

Key benefits in Data View

  • Addition of a Compact Mode, which simplifies the visualization of both chromatograms and spectra and facilitates speed to data review

  • Usability improvements, including

    • Distance tool snaps to data points

    • Persist last folder location in file browsers

    • Addition of a link scrolling toggle between chromatograms and spectra

Key benefits Data Conversion

  • Improved data conversion speed and quality of results with:

    • GPU-enabled peak processing mechanism that generates .mzML up to 3.5x faster

    • Improved deconvolution algorithm offering more reliable results for Isotope3D deconvolution results for Pseudo DDA and component text file output when using Peptide data.

Acquisition Kit

Acquisition Kit

waters_connect Acquisition Kit comprises of Sample Submission, Method Editor and Laboratory Network Device applications. This kit enables data acquisition with third party GC instruments and Waters instrument systems used with waters_connect Quantitative analysis software, such as Xevo TQ-S cronos, Xevo TQ-S micro, Xevo TQ-XS, Xevo TQ Absolute and Xevo TQ Absolute XR & accurate mass applications with Xevo G2-XS QTof, Xevo G3 QTof, Xevo MRT, Xevo MRT P10, Xevo CDMS, BioAccord LC-MS System and ACQUITY RDa Detector.

Versions released

waters_connect 4.5.0 is compatible with Acquisition Kit 3.6.0

Acquisition Kit 3.6.0 is the latest release and includes waters_connect applications such as Sample Submission 2.11.0, Method Editor 4.8.0 and LND 1.27.0.

Benefits

Key Benefits in Acquisition Kit 3.6.0 include:

This release introduces enhancements across the Acquisition Kit to improve workflow flexibility.

  • Enabled review and approval workflows in regulated environments by adding support for generating PDF reports of sample lists.

  • Improved flexibility and productivity by allowing users to add, modify, or delete samples in running acquisitions and resubmit changes without recreating the acquisition.

  • Extend instrument systems configuration capabilities with support for Xevo TQ Absolute XR with LockSpray/low flow ESI probe and ACQUITY M-Class, and compatibility of Evosep Eno LC across Xevo MRT, Xevo MRT P10 and Xevo TQ Absolute XR.

  • Added support for deleting custom plates.

MS Quan

MS Quan

waters_connect MS Quan application is a quantitative analysis software available on our core Xevo tandem quadrupole family of mass spectrometers and the Xevo MRT Product Range (only for Tof MRM acquisition types). It enables routine small-molecule quantitation and accelerates quantitation data processing and review steps with exception-focused review and easy-to-view chromatogram windows for multiple samples.

Versions released

waters_connect 4.5.0 is compatible with MS Quan 2.6.0 & MS Quan 3.0.0.

Benefits

Key Benefits in MS Quan 3.0 include: 

MS Quan 3.0 introduces machine learning for peak integration. 

The knowledge of your laboratory experts is captured in a trained method and can be applied to future data.  This provides: 

  • Reduced manual review time, and increased laboratory productivity and throughput 

  • Standardised peak integration and improved consistency 

  • Improve confidence in quantitative results 

  • Full traceability and audit trailed compliance 

Other enhancements in MS Quan 3.0: 

  • Recording of larger and smaller sample factors enabled to allow greater flexibility in adjusting concentrations using user-defined factors and divisors.

  • Analyte sorting options introduced to allow both alphanumeric and method order sorting of tables and chromatograms 

Key Benefits in MS Quan 2.6.0 include:

MS Quan 2.6 now includes custom calculations providing the flexibility to define user specified calculations within processing methods to support analytical needs.  This provides:

·       Increased review speed​ as calculations run automatically and update in real-time with changes to the batch

·       Greater control of calculations​ by bringing external Excel calculations into compliance control with full audit and edit permission for calculations.

·       Reduced Risk​ by removing the need for validated Excel sheets. Changes to the method are tracked and audited.

·       Calculated values and results can be printed to pdf or exported to LIMS via csv or API.

Includes a new by injection pivot is available for the data summary page allowing customers to visualize the analytes in an injection when this is a more appropriate view of the data.

In addition, data export to csv can now be configured to integrate directly with downstream integration specifications.

UNIFI

UNIFI

waters_connect UNIFI application enables the execution of accurate mass experiments ranging from Small Molecules to Biologics. Moreover, it provides access to core applications such as System Console, Device Management, Explorer, and Qualification for general system use.

Versions released

waters_connect 4.5.0 is compatible with UNIFI 3.19.0

Benefits

Key Benefits in UNIFI 3.19.0 include accurate mass workflow improvements, such as:

  • Accurate Mass Screening (DDA) with more reliable peak identification, ion ratio calculations, common neutral loss searches, and common fragment assignment.

  • The ability to process the MSE data set acquired using Mixed Mode on the Xevo MRT Systems.

  • Improved small molecule accurate mass data processing workflows with more robust drift time plots and calculations for SELECT SERIES Cyclic IMS and Cyclic IMS P20. Introducing support for multipass calibration capabilities for Cyclic IMS P20.

  • More robust MassLynx data import handling.

  • Enhanced event logging for clearer tracking of abort actions.

  • Resolved concurrency issues when running multiple UNIFI utility applications simultaneously.

Pattern Analysis

Pattern Analysis

The waters_connect Pattern Analysis application increases data clarity in complex assays and enhances the confidence in identifying contaminants, such as polymers, PFAS and PCBs.

Versions released

waters_connect 4.5.0 is compatible with Pattern Analysis 1.1.0.

Benefits

Key Benefits in Pattern Analysis 1.1.0 include:

  • Ability to process MS data that has been acquired together with PDA data.

  • Introduce the ability to Create, Clone, Delete and Select Pattern Analysis methods.

  • Ability to specify a m/z range for data processing and detect monomer sequences based on the specified mass range.

  • Components can be banked and unbanked from the Component List table.

  • Enable library searching to be performed with respect to retention time in addition to mass.

  • Filtered components can be exported as a Pattern Analysis library.

  • Ability to change the default assignment when multiple targets are assigned to a component.

*Note: Application has not yet been validated with SONAR Pulse data types

Peptide MAM

Peptide MAM

waters_connect Peptide Multi-Attribute Monitoring (MAM) application enables monitoring of biopharmaceutical product quality attributes (PQA) at the peptide level.

Versions released

waters_connect 4.5.0 is compatible with Peptide MAM 1.8.3.

Benefits

Key Benefits in Peptide MAM 1.8.3 include:

  • General maintenance release

  • Defect fixes

Intact Mass

Intact Mass

waters_connect Intact Mass application enables biologics mass confirmation and purity determination of oligonucleotides, peptides, protein and conjugates.

Versions released

waters_connect 4.5.0 is compatible with Intact Mass 1.9.0.

Benefits

Key Benefits in Intact Mass 1.9.0 include:

  • Automated Calculations of DAR and Drug Distribution for Conjugated Molecule Analysis - users can now deploy a BioAccord System, Xevo G3 QTof, or Xevo MRT QTof to analyze conjugated molecules, specifying the conjugate and its mass in the Intact Mass data processing parameters, and have the calculation of Drug Antibody Ratio and distribution of conjugate forms automatically performed from the acquired data.

  • Controls for manual adjustments of chromatographic integration - users can now manually adjust chromatographic peak integration and associated peak identification results and use those reintegrated peaks to direct the processing of mass spectral data.

  • Sample List Entry of Chemical Formula - users can now specify a ‘Chemical formula for deconvolution’ that will be used to refine the deconvolution isotope model, improving deconvolution mass accuracy and quantification.

  • Updated Sample List Column ‘Expected Masses’ changed to ‘Expected Masses and/or Chemical Formulas’ - users now can enter targets as numeric masses, as chemical formulas, or a mixture of both.

  • New Method option within ‘Specify calculation parameters’, allowing the user more control over the ‘Main Peak Retention Time Window’ to improve main peak identification in Optical Only and Variant Analysis workflows

  • Bioprocessing workflow: Additional sample list columns for Time Point and Dilution Factor that facilitates processing time series trending data (in bioprocess monitor or in third party solutions) and dilution factor to enable clearer results visualization and trending.

  • Application compatibility with data management.

Synthetic Library

Synthetic Library

waters_connect Synthetic Library supports the Confirm Sequence and Map Sequence applications for oligo sequencing and mapping workflows.

Versions released

waters_connect 4.5.0 is compatible with Synthetic Library 2.0.0.

Benefits

Key Benefits in Synthetic Library 2.0.0 include:

  • Support for oligo mapping workflow - new enzymes and polynucleotides sections

  • Multiple library support including user access controls

CONFIRM Sequence

CONFIRM Sequence

waters_connect Confirm Sequence enables streamlined oligonucleotide sequence confirmation and impurity characterization workflow.

Versions released

waters_connect 4.5.0 is compatible with Confirm Sequence 2.1.1

Benefits

Key Benefits in Confirm Sequence 2.1.1 include:

  • General maintenance release

  • Defect fixes

Map Sequence

Map Sequence

waters_connect Map Sequence enables accurate mass mapping of digested oligonucleotides.

Versions released

waters_connect 4.5.0 is compatible with Map Sequence 2.0.0.

Benefits

Key Benefits in Map Sequence 2.0.0 include:

  • Supported by Synthetic Library for sequence entry and experimental planning

  • Oligo mapping and sequence confirmation using LCMSE precursor and fragment data

  • Interactive annotated chromatogram

  • Interactive coverage map for simple visualization of sequence coverage and navigation to supporting data

  • Drill-down to fragment analysis

  • Dynamic pass-fail filtering and acceptance criteria for investigation and curation of results

  • Integrated reporting

Bioprocess Monitor

Bioprocess Monitor

The waters_connect Bioprocess Monitor application enables routine, in-process monitoring of spent media components and product titer via absolute and relative quantification using LC/UV, LC/MS & LC-UV/MS techniques.

Versions released

waters_connect 4.5.0 is compatible with Bioprocess Monitor 1.2.0.

Benefits

Key benefits in Bioprocess Monitor 1.2.0 include:

  • Analytical Capability - Expanded detection with FLR support to enhance sensitivity and confidence in measurements

  • Compliance - Support for GMP environments with role-based restrictions and action comments

  • Connectivity - Scalable deployment enabled through waters_connect network support

  • Global Access - Improved usability with Japanese localisation

CDMS Toolkit

CDMS Toolkit

The waters_connect CDMS Toolkit application empowers customers to unlock the full potential of Xevo CDMS by enabling access to real-time data acquisition, native analysis, and advanced visualization, streamlining workflows and accelerating insights into large, complex biomolecules.

Versions released

waters_connect 4.5.0 is compatible with CDMS Toolkit 1.0.0.

Benefits

Key benefits in CDMS Toolkit 1.0.0 include:

  • Enables native analysis of large protein assemblies and multi-subunit complexes, including tools for assessing molecular weight, purity, and heterogeneity.

  • Real-time display of mass, mass-to-charge, and charge spectra, along with corresponding 2-dimensional heatmaps.

  • Raw data review for pre-acquired and live acquisition.

  • Relative quantitation analysis to determine quantities of user defined targets.

  • Application compatibility with data management.

MS Imaging

MS Imaging

The MS Imaging application with waters_connect control enables customers to generate molecular spatial information directly from surfaces using the DESI XS Xevo MRT MS system solution. The integration of DESI XS with Xevo MRT MS enables high spatial resolution, label-free molecular imaging directly from sample surfaces with minimal preparation, offering highly sensitive MS Imaging at speeds of up to 100 Hz, with sub-ppm mass accuracy, making it ideal for applications in biomedical research, drug distribution studies, and forensic analysis.

Versions released

waters_connect 4.5.0 is compatible with MS Imaging 1.1.0 in combination with Xevo MRT v1.7.1 and Xevo MRT P10 v1.7.1 drivers.

Benefits

Key benefits in MS Imaging 1.1.0 include:

  • General anomaly corrections such as ImzmlConverter now supports processing DESI Xevo MRT data.

Applications

waters_connect for Quantitation

waters_connect for Quantitation

Quantitative analysis software available on our core Xevo tandem quadrupole family of mass spectrometers and Xevo MRT Product Range, enabling laboratories to process large sample batches quickly and easily, significantly reducing the time spent on data review. Maximize your productivity with a compliant-ready workflow for analytical methodologies ranging from PFAS to genotoxic impurity analysis.

Acquisition

  • Sample Submission 2.11.0 [new]

  • Acquisition Method Editor 4.8.0 [new]

  • Laboratory Network Device 1.27.0 [new] 

  • Cloud Edge software for System Monitoring (latest available)

 

Data View & Processing

  • LC-MS Toolkit 1.20.0 [new]
  • MS Quan 2.6.0
  • MS Quan 3.0.0 [new]

Instrument Drivers

  • ACQUITY UPLC DP 3.9.0

  • 3rd Party ICF 3.1.0

  • Xevo TQ-S cronos 2.2.0 [new]

  • Xevo TQ-S micro 2.2.0 [new]

  • Xevo TQ-XS 2.2.0 [new]

  • Xevo TQ Absolute 2.2.0 [new]

  • Xevo TQ Absolute XR 2.2.0 [new]

  • Xevo MRT 1.7.1 [new]

  • Xevo MRT P10 1.7.1 [new]

    *for Tof MRM

waters_connect for Biopharma

waters_connect for Biopharma

Biopharmaceutical accurate mass applications for protein-based therapeutics, vaccines, and nucleic acid-based therapeutics.

Acquisition

  • Sample Submission 2.11.0 [new]

  • Acquisition Method Editor 4.8.0 [new]

  • Laboratory Network Device 1.27.0 [new] 

  • Cloud Edge software for System Monitoring (latest available)

Data View & Processing

  • LC-MS Toolkit 1.20.0 [new]

  • UNIFI 3.19.0 [new] 

  • Data Convert 5.0.0 [new] 

  • Peptide MAM 1.8.3

  • Intact Mass 1.9.0

  • Bioprocess Monitor 1.2.0

  • MAP Sequence 2.0.0

  • Synthetic Library 2.0.0

  • Confirm Sequence 2.1.1 [new] 

Instrument Drivers

  • ACQUITY UPLC DP 3.9.0
  • 3rd Party ICF 3.1.0

  • BioAccord 3.5.0

  • Xevo G2-XS QTof 4.4.0

  • Xevo G3 QTof 1.4.0

  • Xevo MRT 1.7.1 [new]

  • Xevo MRT P10 1.7.1 [new]

  • Vion IMS QTof 4.3.0

waters_connect for Bioprocessing

waters_connect for Bioprocessing

Bioprocess accurate mass applications for process (spent cell culture media) and product quality attribute monitoring with the BioAccord LC-MS system and Bioprocess Walk-Up Solutions.

Acquisition

  • Sample Submission 2.11.0 [new]

  • Acquisition Method Editor 4.8.0 [new]

  • Laboratory Network Device 1.27.0 [new] 

  • Cloud Edge software for System Monitoring (latest available)

Data View & Processing

  • LC-MS Toolkit 1.20.0 [new]
  • UNIFI 3.19.0 [new] 

  • Peptide MAM 1.8.3

  • Intact Mass 1.9.0

  • Bioprocess Monitor 1.2.0

Instrument Drivers

  • ACQUITY UPLC DP 3.9.0
  • BioAccord 3.5.0

waters_connect for CDMS

waters_connect for CDMS

Achieve precise mass measurement of challenging large and highly heterogeneous biologics including viral vectors, virus-like particles (VLPs), RNA, and protein complexes that were previously out of reach for mass characterization.

Acquisition

  • Sample Submission 2.11.0 [new]
  • Acquisition Method Editor 4.8.0 [new]

  • Laboratory Network Device 1.27.0 [new] 

Data View & Processing

  • CDMS Toolkit 1.0.0

     

     

Instrument Drivers

  • Xevo CDMS 1.0.0

     

     

waters_connect for Small Molecules

waters_connect for Small Molecules

Accurate mass-based solutions for targeted and non-targeted screening of small molecules, offering versatile qualitative and quantitative analysis of compounds such as pesticides, drugs of abuse, metabolites, impurities, extractables and leachables, and identification of contaminants like polymers, PFAS, and PCBs in complex samples.

Acquisition

  • Sample Submission 2.11.0 [new]

  • Acquisition Method Editor 4.8.0 [new]

  • Laboratory Network Device 1.27.0 [new] 

  • Cloud Edge software for System Monitoring (latest available)

Data View & Processing

  • LC-MS Toolkit 1.20.0 [new]
  • UNIFI 3.19.0 [new] 

  • Pattern Analysis 1.1.0

  • Data Convert 5.0.0 [new]

Instrument Drivers

  • ACQUITY UPLC DP 3.9.0
  • 3rd Party ICF 3.1.0

  • ACQUITY RDa 3.5.0

  • Xevo G2-XS QTof 4.4.0

  • Xevo G3 QTof 1.4.0

  • Xevo MRT 1.7.1 [new]

  • Xevo MRT P10 1.7.1 [new]

  • Vion IMS QTof 4.3.0

waters_connect for Data Readiness

waters_connect for Data Readiness

Accurate mass-based metabolomics, lipidomics and metabolite identification solutions with integration with 3rd Party software (via .mzML and/or via API)

Acquisition

  • Sample Submission 2.11.0 [new]

  • Acquisition Method Editor 4.8.0 [new]

  • Laboratory Network Device 1.27.0 [new] 

  • Cloud Edge software for System Monitoring (latest available)

Data View & Processing

  • LC-MS Toolkit 1.20.0 [new]

  • Data Convert 5.0.0 [new]

 

Instrument Drivers

  • ACQUITY UPLC DP 3.9.0
  •  ACQUITY RDa 3.5.0

  • Xevo G2-XS QTof 4.4.0

  • Xevo G3 QTof 1.4.0

  • Xevo MRT 1.7.1 [new]

  • Xevo MRT P10 1.7.1 [new]

waters_connect for Imaging

waters_connect for Imaging

Generate molecular spatial information directly from surfaces with Mass Spectrometry Imaging and the powerful integration of DESI XS with Xevo MRT MS.

Acquisition

  • MS Imaging 1.1.0
  • Sample Submission 2.11.0 [new]

  • Acquisition Method Editor 4.8.0 [new]

  • Laboratory Network Device 1.27.0 [new] 

Data View & Processing

  • Waters HDI 1.9.1

Instrument Drivers

  • Xevo MRT 1.7.1 [new]

  • Xevo MRT P10 1.7.1 [new]

  •  

Configurations

This section provides an overview on supported operating systems, maximum number of instrument systems in a Network install and inlets modules such as pumps, detectors, sample managers, column compartments available in waters_connect 4.5.0.

Operating System Support for Workstation Installs

Operating System Support for Workstation Installs

Operating System
Windows

Requirements

  • OS language: English (US), Japanese (Japan).

  • Windows images provided with waters_connect PCs include Windows IoT Enterprise licensing which enables extended support on the operating system end of service over the standard edition. For more information on Windows releases visit https://learn.microsoft.com/en-us/windows/release-health/

Versions Supported
Workstation PC

  • Windows 10 Enterprise LTSC 2021 edition (version 21H2)

  • Windows 10 Enterprise IoT LTSC 2021 edition (version 21H2)

  • Windows 11 Enterprise LTSC 2024 edition (version 24H2)

  • Windows 11 Enterprise IoT LTSC 2024 edition (version 24H2)

  • Windows 11 Pro version 24H2

Operating System Support for Network Installs

Operating System Support for Network Installs

Operating System
Windows

Requirements

  • OS language: English (US), Japanese (Japan). Note: for Client PCs only the software deployment is supported on European and Japanese language versions of Windows.  However, Hub is displayed in English (US) or Japanese (Japan) only.

  • Windows images provided with waters_connect PCs include Windows IoT Enterprise licensing which enables extended support on the operating system end of service over the standard edition. For more information on Windows releases visit https://learn.microsoft.com/en-us/windows/release-health/

Versions Supported

Server PC

  • Windows Server 2025 Standard Edition

  • Windows Server 2019 Standard Edition

  • Note 1: Mainstream support for Windows Server 2019 Standard ended, recommend to adopt the latest Windows Server OS.
  • Note 2: OS In-upgrade is supported.

 

LND PC

  • Windows 10 Enterprise LTSC 2021 Edition (version 21H2)

  • Windows 10 Enterprise IoT LTSC 2021 Edition (version 21H2)

  • Windows 11 Enterprise IoT LTSC 2024 Edition (version 24H2) [new] 

Client PC

  • Windows 10 Enterprise LTSC 2021 Edition (version 21H2)

  • Windows 10 Enterprise IoT LTSC 2021 Edition (version 21H2)

  • Windows 11 Enterprise LTSC 2024 Edition (version 24H2)

  • Windows 11 Pro version (24H2)

  • Windows Server 2025 Standard Edition

  • Windows Server 2019 Standard Edition

 

  • Note: Windows 11 and Windows Server 2025 introduce updates to underlying math libraries, floating-point handling, and processor optimizations that can lead to slight differences in calculated values compared to previous Windows versions.

Mass spectrometry instruments supported on a single waters_connect network deployment

Mass spectrometry instruments supported on a single waters_connect network deployment

Instrument Type

Instrument Type

Instrument Type

Instrument Type

Instrument Type

Instrument Type

Instrument

Total Number of Systems

Recommended Number of Client PCs

Recommended Number of Users

Tof

Tof

Tof

Tof

Tof

Tof

  • ACQUITY RDa
  • BioAccord LCMS system 
  • Mix of Tof

up to 6

up to 6

  • up to 10 (concurrent)
  • up to 100 (active software accounts)

QTof

QTof

QTof

QTof

QTof

QTof

  • Xevo G2-XS QTof
  • Xevo G3 QTof
  • Vion IMS QTof
  • Mix QTof (excluding Xevo MRT)

up to 4

up to 4

  • up to 10 (concurrent)
  • up to 100 (active software accounts)

QTof

QTof

QTof

QTof

QTof

QTof

  • Xevo MRT
  • Xevo MRT P10
  • Xevo MRT and Xevo MRT P10 are not supported on the same network at the same time

up to 2

up to 4

  • up to 4 (concurrent)
  • up to 100 (active software accounts)

Tof & QTof

Tof & QTof

Tof & QTof

Tof & QTof

Tof & QTof

Tof & QTof

  • Mix of Tof and QTof
  • Xevo G2-XS QTof
  • Xevo G3 QTof
  • Vion IMS QTof
  • Mix QTof (excluding Xevo MRT)

 

up to 4 in the following combos:

  • up to 4 Tof/QTof (excluding Xevo MRT)

  • up to 2 Xevo MRT + 1 QTof + 1 Tof

  • up to 2 Xevo MRT + 2 Tof

up to 4

  • up to 10 (concurrent)

  • up to 100 (active software accounts)

TQ

TQ

TQ

TQ

TQ

TQ

  • Xevo TQ-S cronos
  • Xevo TQ-S micro
  • Xevo TQ-XS 
  • Xevo TQ Absolute
  • Xevo TQ Absolute XR
  • Mix of Quads 

up to 9

up to 9

  • up to 10 (concurrent)
  • up to 100 (active software accounts)

TQ, Tof, & QTof

TQ, Tof, & QTof

TQ, Tof, & QTof

TQ, Tof, & QTof

TQ, Tof, & QTof

TQ, Tof, & QTof

  • Mix of Quads & QTofs/Tofs
    (excluding Xevo MRT/Xevo MRT P10)

up to 6 in the following combos:

  • up to 3 TQ + up to 3 QTof

  • up to 4 TQ + up to 2 QTof

  • up to 3 TQ + up to 2 QTof + 1 Tof

  • up to 3 TQ + 1 QTof + 2 Tof

  • up to 3 TQ + up to 3 Tof

up to 6

  • up to 10 (concurrent)
  • up to 100 (active software accounts)

TQ, Tof & QTof

TQ, Tof & QTof

TQ, Tof & QTof

TQ, Tof & QTof

TQ, Tof & QTof

TQ, Tof & QTof

  • Mix of Quads & QTofs/Tofs
    (with Xevo MRT/ Xevo MRT P10)

up to 5 in the following combos:

  • up to 2 Xevo MRT/ Xevo MRT P10 + 1 QTof + 1 Tof + 1 TQ (Xevo MRT and Xevo MRT P10 on the same network is not supported)

  • up to 2 Xevo MRT/ Xevo MRT P10 + up to 2 Tof + 1 TQ

  • up to 2 Xevo MRT/ Xevo MRT P10 + up to 3 TQ

up to 5

  • up to 10 (concurrent)
  • up to 100 (active software accounts)

Instrument systems modules supported (such as pumps, detectors, sample managers, column compartments)

Instrument systems modules supported (such as pumps, detectors, sample managers, column compartments)

Note: full information on new features and quality improvements and more is available in the appropriate instrument model release notes at waters.com


Gas Chromatography systems

Gas Chromatography systems

Agilent GC system

Agilent GC system

GC Configuration

  • Agilent 8890 GC

  • Agilent 7693A Automatic Liquid Sampler

  • CTC PAL3 Series 2 Autosampler

Acquisition Apps

  • Sample Submission

Supported MS Instruments

  • Xevo G3 QTof with Waters Atmospheric Pressure Gas Chromatography (APGC) source

  • Xevo TQ Absolute with Waters APGC source

  • Xevo TQ Absolute XR with Waters APGC source

Microscale ACQUITY UPLC systems

Microscale ACQUITY UPLC systems

ACQUITY UPLC M-Class

ACQUITY UPLC M-Class

UPLC Configuration

  • uBinary Solvent Manager
  • uSample Manager-Fixed Loop

  • Auxillary Solvent Manager

  • Trap Valve Manager

Acquisition Apps

  • Sample Submission

Supported MS Instruments

  • Xevo MRT/ Xevo MRT P10 with NanoLockSpray and low-flow ESI probe

  • Xevo G3 QTof with NanoLockSpray and low-flow ESI probe

  • Xevo G2-XS QTof with low-flow ESI probe only 

  • Xevo TQ Absolute XR with nanoflow source

Evosep ENO LC

Evosep ENO LC

UPLC Configuration

  • Evosep ENO

Acquisition Apps

  • Sample Submission

Supported MS Instruments

  • Xevo TQ Absolute XR with nanoflow source

  • Xevo MRT/ Xevo MRT P10 with NanoLockSpray and low-flow ESI probe

Analytical ACQUITY UPLC systems

Analytical ACQUITY UPLC systems

ACQUITY Premier/ACQUITY H-Class Binary Series (15,000 PSI limited systems)

ACQUITY Premier/ACQUITY H-Class Binary Series (15,000 PSI limited systems)

UPLC Configuration

  • Binary Solvent Manager (BSM)
  • Sample Manager - Flow Through Needle (SM-FTN)

  • Sample Manager – Fixed Loop (SM-FL)

  • Column Heater (CH-A)

  • Column Manager CM/CHC 30cm

  • Column Manager (CM-A/CM-Aux)*

    *Note: with Sample Submission up to 2 CM-Aux units using 6 columns

Acquisition Apps

  • Sample Submission (S)
  • UNIFI (U)

Supported MS Instruments

  • Xevo TQ-S cronos (S)
  • Xevo TQ-S micro (S) 

  • Xevo TQ-XS (S)

  • Xevo TQ Absolute (S)

  • Xevo TQ Absolute XR (S)

  • BioAccord (S & U)

  • ACQUITY RDa (U)

  • Xevo G2-XS QTof (S & U)

  • Xevo G3 QTof (S & U)

  • Vion IMS QTof (U)

  • Xevo MRT (S)

  • Xevo MRT P10 (S)

ACQUITY Premier/ACQUITY H-Class Quaternary Series (15,000 PSI limited systems)

ACQUITY Premier/ACQUITY H-Class Quaternary Series (15,000 PSI limited systems)

UPLC Configuration

  • Quaternary Solvent Manager (QSM)
  • Sample Manager - Flow Through Needle (SM-FTN)

  • Sample Manager – Fixed Loop (SM-FL)

  • Column Heater (CH-A)

  • Column Manager CM/CHC 30cm

  • Column Manager (CM-A/CM-Aux)*

    *Note: with sample Submission up to 2 CM-Aux units using 6 columns and Solvent Select Valve.

Acquisition Apps

  • Sample Submission (S)
  • UNIFI (U)

Supported MS Instruments

  • Xevo TQ-S cronos (S)
  • Xevo TQ-S micro (S) 

  • Xevo TQ-XS (S)

  • Xevo TQ Absolute (S)

  • Xevo TQ Absolute XR (S)

  • BioAccord (S & U)

  • ACQUITY RDa (U)

  • Xevo G2-XS QTof (S & U)

  • Xevo G3 QTof (S & U)

  • Vion IMS QTof (U)

  • Xevo MRT (S)

  • Xevo MRT P10 (S)

ACQUITY UPLC I-Class Plus Series (18,000 PSI limited systems)

ACQUITY UPLC I-Class Plus Series (18,000 PSI limited systems)

UPLC Configuration

  • Solvent Manager (BSM)
  • Sample Manager - Flow Through Needle (SM-FTN)

  • Sample Manager – Fixed Loop (SM-FL)

  • Column Heater (CH-A)

  • Column Manager (CM-A)

Acquisition Apps

  • Sample Submission (S)
  • UNIFI (U)

Supported MS Instruments

  • Xevo TQ-S cronos (S)
  • Xevo TQ-S micro (S) 

  • Xevo TQ-XS (S)

  • Xevo TQ Absolute (S)

  • Xevo TQ Absolute XR (S)

  • BioAccord (S & U)

  • ACQUITY RDa (U)

  • Xevo G2-XS QTof (S & U)

  • Xevo G3 QTof (S & U)

  • Vion IMS QTof (U)

  • Xevo MRT (S)

  • Xevo MRT P10 (S)

ACQUITY UPLC Series (15,000 PSI limited systems)

ACQUITY UPLC Series (15,000 PSI limited systems)

UPLC Configuration

  • Binary Solvent Manager (BSM)
  • Sample Manager – Fixed Loop (SM-XY)

  • Column Heater HTCH

  • Column Manager CM/CHC

Acquisition Apps

  • UNIFI

Supported MS Instruments

  • ACQUITY RDa

  • Xevo G2-XS QTof

ACQUITY UPLC Tunable UV (TUV) Detector

ACQUITY UPLC Tunable UV (TUV) Detector

Acquisition Apps

  • Sample Submission (S)
  • UNIFI (U)

Supported MS Instruments

  • Xevo TQ-S cronos (S)
  • Xevo TQ-S micro (S) 

  • Xevo TQ-XS (S)

  • Xevo TQ Absolute (S)

  • Xevo TQ Absolute XR (S)

  • BioAccord (S & U)

  • ACQUITY RDa (U)

  • Xevo G2-XS QTof (S & U)

  • Xevo G3 QTof (S & U)

  • Vion IMS QTof (U)

  • Xevo MRT (S)

  • Xevo MRT P10 (S)

ACQUITY UPLC Photodiode Array (PDA)/eLambda PDA Detector (1; 2)

ACQUITY UPLC Photodiode Array (PDA)/eLambda PDA Detector (1; 2)

Acquisition Apps

  • Sample Submission (S)
  • UNIFI (U)

Supported MS Instruments

  • Xevo TQ-S cronos (S)
  • Xevo TQ-S micro (S) 

  • Xevo TQ-XS (S)

  • Xevo TQ Absolute (S)

  • Xevo TQ Absolute XR (S)

  • BioAccord (S & U)

  • ACQUITY RDa (U)

  • Xevo G2-XS QTof (S & U)

  • Xevo G3 QTof (S & U)

  • Vion IMS QTof (U)

  • Xevo MRT (S)

  • Xevo MRT P10 (S)

ACQUITY UPLC Fluorescence (FLR) Detector

ACQUITY UPLC Fluorescence (FLR) Detector

Acquisition Apps

  • Sample Submission (S)

  • UNIFI (U)

Supported MS Instruments

  • Xevo TQ-S cronos (S)

  • Xevo TQ-S micro (S) 

  • Xevo TQ-XS (S)

  • Xevo TQ Absolute (S)

  • Xevo TQ Absolute XR (S)

  • BioAccord (S & U)

  • ACQUITY RDa (U)

  • Xevo G2-XS QTof (S & U)

  • Xevo G3 QTof (S & U)

  • Vion IMS QTof (U)

  • Xevo MRT (S)

  • Xevo MRT P10 (S)

ACQUITY Common Platform Sample Organizer (CPSO)

ACQUITY Common Platform Sample Organizer (CPSO)

Acquisition Apps

  • Sample Submission (S)
  • UNIFI (U)

Supported MS Instruments

  • Xevo TQ-S cronos (S)

  • Xevo TQ-S micro (S) 

  • Xevo TQ-XS (S)

  • Xevo TQ Absolute (S)

  • Xevo TQ Absolute XR (S)

  • BioAccord (S & U)

  • ACQUITY RDa (U)

  • Xevo G2-XS QTof (S & U)

  • Xevo G3 QTof (S & U)

  • Vion IMS QTof (U)

  • Xevo MRT (S)

  • Xevo MRT P10 (S)

ACQUITY eSAT/IN Module

ACQUITY eSAT/IN Module

Acquisition Apps

  • UNIFI

Supported MS Instruments

  • BioAccord
  • ACQUITY RDa

  • Xevo G2-XS QTof

  • Xevo G3 QTof

  • Vion IMS QTof

DESI XS Module

DESI XS Module

Acquisition Apps

  • MS Imaging

Supported MS Instruments

  • Xevo MRT/ Xevo MRT P10