Tip #229: Truncating Numbers in Custom Fields in Empower

Tip #229: Truncating Numbers in Custom Fields in Empower

In this tip, we will learn how to truncate numbers in a Custom Field.

In Tip 227, we learned how to round numbers. There may be times when you need to simply truncate or shorten a number without rounding, to accomplish this, we use the Round function in a Custom Field.

STEP 1

STEP 1

Figure 1 is a summary of the syntax used for the Custom Fields used to truncate numbers either to the left or the right of the decimal point.

STEP 2

STEP 2

In the first example, you want to truncate the USP signal to noise ratio (s/n) to the second number to the right of the decimal point.

STEP 3

STEP 3

Create a Custom Peak field, ‘Data Type Real’.

STEP 4

STEP 4

The result is a truncated value of the USP signal to noise ratio (s/n).

STEP 5

STEP 5

In the second example, you want to truncate Peak Area to the second number to the left of the decimal point. Peak Area is a real number, however, Empower defaults to displaying Area as a whole number.

STEP 6

STEP 6

Create another Custom Peak field, ‘Data Type Real’.

STEP 7

STEP 7

The result is a truncated value of the Peak Area.

It’s that easy!

Final Notes

You can use either the Pro or QuickStart interface for this tip.