waters_connect 3.2.0 LTS Release Overview

waters_connect 3.2.0 LTS Release Overview

Introduction

Introduction

This page provides an overview of the waters_connect 3.2.0 LTS release, compatible waters_connect applications, instrument drivers and supported system configurations including liquid chromatography modules, mass spectrometry instruments, and detectors. For more information on waters_connect release types and associated level of software support please visit waters_connect Releases Overview.

Release Overview

Recommended Use

waters_connect helps you accelerate the time to outcomes with workflow solutions ranging from quantitative, biopharma, and accurate mass-based analyses helping you reach new levels of efficiency, precision, and confidence.

Key Solutions Available with this Release

  • waters_connect for Quantitation — Quantitative analysis software available on our core Xevo tandem quadrupole family of mass spectrometers to enable laboratories to process large sample batches quickly and easily, significantly reducing the time spent on data review. Maximize your productivity with workflows for tailored for Food and Environmental analysis.
  • waters_connect for Biopharma — Accurate mass applications for protein-based therapeutics, vaccines, and nucleic acid-based therapeutics including applications for bioprocessing (spent cell culture media) and product quality attribute monitoring.
  • waters_connect for Small Molecules — Accurate mass-based solutions for screening of small molecules with versatile qualitative and quantitative analysis of compounds like pesticides, drugs of abuse, metabolites, impurities, extractables, and leachables.

Key Benefits

Key Benefits

Base Kit

Base Kit

waters_connect Base Kit comprises of platform services, utility tools and core applications such as Hub, Administration, System Console, Device Management, Explorer, Qualification for general system use.

Key benefits in this release include:

  • Elevate your product understanding when using the waters_connect for Quan and the Biologics workflows with the software translation in Japanese.
  • Increased compliance readiness with more comprehensive insights in the audit trail for acquisition events and acquisition method, such as:
    • advanced user setting restrictions for customizable reports,
    • better traceability in the audit trail for records (such as methods, experimental records, post run reports and instrument details) associated to a data set,
    • view records in draft within the Explorer application.
  • Improve your lab productivity and reduce instrument cost of ownership by connecting up to 5 Xevo Tandem Quadrupole instruments in a single network deployment.
  • Extend the capabilities of your instrument systems inlet and sources with the support for multidimensional liquid chromatography with ACQUITY UPLC System with 2D LC Technology for accurate mass workflows within the UNIFI application.
  • Improved product robustness and stability when acquiring with the Laboratory Network Device (LND) application reduce data transfer communication bottlenecks caused by instrument errors.
  • Improved performance and reliability of waters_connect Network deployments with the release of a new waters_connect LND PC.
  • Improved robustness and performance when importing MassLynx data.
  • Increased usability and productivity for the waters_connect acquisition workflow with the Device Management application. This enables you to manage your laboratory network devices, instrument systems, clients and the instrument drivers;
    • one-click set-up of systems on/offline in System Console;
    • view of diagnostic channels in Sample Submission and Toolkit applications.
  • Elevated usability of the UNIFI application with user interface improvements, such as redesigned icons, more data available to fit in the vertical space of your screen, more visible scrollbars and dynamic zoom in/out adjustments for tabular data;
  • Improved product quality and stability by addressing high impact software anomalies such as:
    • sample tray default to ANSI-48 Vial 2ML;
    • loading time of waters_connect applications;
    • MS Quan result set character limits & draft statuses;
    • UNIFI high energy fragment table for candidate components;
    • UNIFI DDA & MSMS data send/retrieve detection results to Scientific Library.

LC-MS Toolkit

LC-MS Toolkit

The LC-MS Toolkit application enables data interrogation outside of the defined workflows; provides flexibility to the software that is needed for more advanced use.

Key benefits in this release include:

  • Expanded tools for basic accurate mass analysis in Toolkit such as lock mass channel, combine to view spectra, Integrate, Smooth, Mass Measure, Spectra Background Subtract, Chromatograms Combine and Subtract, improved zoom functionality, and Tof/quad centroided spectra continuum data.
  • The ability to create a peak list table from a chromatogram, detailing RT, Area, % Area, Height, % Height, Width, and Data Points Across the Peak
  • An elemental composition calculator is included that calculates possible formulas that could account for an observed accurate mass. You can also analyze low-energy and high-energy MSe data to include a high-energy fragment in the calculation.
  • Localization into Japanese.

Acquisition Kit

Acquisition Kit

waters_connect Acquisition Kit comprises of Sample Submission, Method Editor and Laboratory Network Device applications. This kit enables data acquisition with Waters instrument systems used accurate mass Biopharmaceutical applications with Xevo G2-XS QTof, Xevo G3 QTof and BioAccord system & the quantitation workflow with Xevo TQ-S cronos, Xevo TQ-S micro, Xevo TQ-XS and Xevo TQ Absolute. 

Key benefits in this release include:

  • Extend the capabilities of your instrument systems inlet and sources with the support for ACQUITY UPLC M-Class System and NanoLockSpray Ionization Source for Xevo G3 QTof.
  • Increased security with the adoption of Transport Layer Security (TLS) 1.2 for the acquisition workflow when using the Sample Submission and Acquisition Method Editor applications.
  • Increased usability and productivity for the biologics workflows by automating data acquisition and processing for Xevo G2-XS QTof and Xevo G3 QTof, Intact Mass, and Peptide MAM applications.
  • Increased usability and productivity for the waters_connect acquisition workflow by viewing diagnostic channels in the Sample Submission application.
  • Localization into Japanese.

MS Quan

MS Quan

The MS Quan application enables routine small-molecule quantitation and accelerates quantitation data processing and review steps with exception-focused review and easy-to-view chromatogram windows for multiple samples.

Key benefits in MS Quan v1.10 release include:

  • Sample factors to allow for sample dilution workflows.
  • Reporting enhancements to allow users to further define the content of the PDF report.
    • Report queue to facilitate generation of multiple reports simultaneously
    • Configuration of data tables (Including/excludes columns and ordering)

    • Optional peak annotations

    • Optional axes labels

    • Extra configurable summary information

    • Visibility of all reports generated in a result set

    • Tables automatically split when too wide

    • Additional ion ratio and qual ion fields

  • Localization into Japanese
  • PFAS enhancements
    • R2 values shown for calibrations where the user forces the origin
    • Lower bound calculations for totals by including the LLOQ value
    • An option to change the linking of Internal standards to secondary internal standards
    • Update of the retention time rule to allow identification of peaks using a relative retention time rule

Key benefits in MS Quan v1.11 release include:

  • Explicit edit and discard actions on methods and results to clarify the situation around saving of data.
  • The clear display of version information for all MS Quan entities. 
  • MS Quan now automatically calculates a recovery % for Primary Internal Standards.
  • Reporting enhancements to allow users to further define the content of the PDF report.
    • Option to set the size of chromatograms and define the axes
    • Filtering of injections/analytes included
    • Inclusion of instrument system type and name
  • Improvements to the manual integration workflows that allow new peaks to be added and defined more reliably

Peptide MAM

Peptide MAM

waters_connect Peptide Multi-Attribute Method (MAM) enables monitoring of biopharmaceutical product quality attributes (PQA) at the peptide level.

Benefits

Key benefits in Peptide MAM 1.8.0 release include:

  • An Application Programming Interface (API) is now available that supports creation of analyses and retrieval of results by third party informatics tools.
  • Enhanced processing of data containing higher mass peptides by an Improved Monoisotopic Peak Detection (IMPD) routine, which supports detection of a lower intensity or missing monoisotopic peak.
  • Localization into Japanese

Key benefits in Peptide MAM 1.8.1 release include:

  • Support for PDA optical detectors. In addition to TUV, users can now view the optical channels from the PDA detector.
  • Support for Sample Organizer, allowing up to19 microtiter plates, or, 9 intermediate height plates, or, 6 deep-well plates. Increasing the potential throughput for Peptide MAM users.

Key Benefits in Peptide MAM 1.8.2 include:

  • General maintenance release

  • Defect fixes

Intact Mass

Intact Mass

waters_connect Intact Mass enables biologics mass confirmation and purity determination of oligonucleotides, peptides, protein and conjugates.

Benefits

Key Benefits in this application include:

  • Automated Calculations of DAR and Drug Distribution for Conjugated Molecule Analysis - Users can now deploy a BioAccord System, Xevo G3 QTof, or Xevo MRT QTof to analyze conjugated molecules, specifying the conjugate and its mass in the INTACT Mass data processing parameters, and have the calculation of Drug Antibody Ratio and distribution of conjugate forms automatically performed from the acquired data.

  • Controls for manual adjustments of chromatographic integration - Users can now manually adjust chromatographic peak integration and associated peak identification results and use those reintegrated peaks to direct the processing of mass spectral data.

  • Sample List Entry of Chemical Formula - User can now specify a ‘Chemical formula for deconvolution’ that will be used to refine the deconvolution isotope model, improving deconvolution mass accuracy and quantification.

  • Updated Sample List Column ‘Expected Masses’ changed to ‘Expected Masses and/or Chemical Formulas’: Users now can enter targets as numeric masses, as chemical formulas, or a mixture of both.

  • New Method option within ‘Specify calculation parameters’, allowing the user more control over the ‘Main Peak Retention Time Window’ to improve main peak identification in Optical Only and Variant Analysis workflows

  • Bioprocessing workflow: Additional sample list columns for Time Point and Dilution Factor that facilitates processing time series trending data (in bioprocess monitor or in third party solutions) and dilution factor to enable clearer results visualization and trending.

Synthetic Library

Synthetic Library

waters_connect Synthetic Library supports the Confirm Sequence and Map Sequence applications for oligo sequencing and mapping workflows.

Benefits

Key Benefits in Synthetic Library 2.0 include:

  • Support for oligo mapping workflow - new enzymes and polynucleotides sections

  • Multiple library support including user access controls

CONFIRM Sequence

CONFIRM Sequence

waters_connect Confirm Sequence enables streamlined oligonucleotide sequence confirmation and impurity characterization workflow.

Benefits

Key Benefits in Confirm Sequence 2.0 include:

  • Compatibility with Synthetic Library 2.0.0

  • Maximum charge state support extended to -20

Map Sequence

Map Sequence

waters_connect Map Sequence enables accurate mass mapping of digested oligonucleotides.

Benefits

Key Benefits in Map Sequence 2.0 include:

  • Supported by Synthetic Library for sequence entry and experimental planning

  • Oligo mapping and sequence confirmation using LCMSE precursor and fragment data

  • Interactive annotated chromatogram

  • Interactive coverage map for simple visualization of sequence coverage and navigation to supporting data

  • Drill-down to fragment analysis

  • Dynamic pass-fail filtering and acceptance criteria for investigation and curation of results

  • Integrated reporting

Note: full information on new features and quality improvements available in the release notes.

Applications

waters_connect for Quantitation

waters_connect for Quantitation

Quantitative analysis software available on our core Xevo tandem quadrupole family of mass spectrometers to enable laboratories to process large sample batches quickly and easily, significantly reducing the time spent on data review. Maximize your productivity with a compliant-ready workflow for analytical methodologies ranging from PFAS to genotoxic impurity analysis.

Acquisition

  • Sample Submission 2.1.0
  • Acquisition Method Editor 3.1.0 
  • Laboratory Network Device 1.16.1

 

Data View & Processing

  • LC-MS Toolkit 1.11.0
  • MS Quan 1.10.0
  • MS Quan 1.11.0
  • MS Quan 1.11.1

Instrument Drivers

  • Xevo TQ-S cronos 1.4.0
  • Xevo TQ-S micro 1.4.0
  • Xevo TQ-XS 1.4.0
  • Xevo TQ Absolute 1.4.0
  • Xevo TQ-S cronos 1.6.0
  • Xevo TQ-S micro 1.6.0
  • Xevo TQ-XS 1.6.0
  • Xevo TQ Absolute 1.6.0

waters_connect for Biopharma

waters_connect for Biopharma

Biopharmaceutical accurate mass applications for protein-based therapeutics, vaccines, and nucleic acid-based therapeutics.

Acquisition

  • UNIFI 3.6.0
  • Laboratory Network Device 1.16.1

 

Data View & Processing

  • LC-MS Toolkit 1.11.0
  • UNIFI 3.6.0
  • Synthetic Library 2.0.0
  • Confirm Sequence 2.0.0
  • MAP Sequence 2.0.0

Instrument Drivers

  • ACQUITY RDa 3.4.0
  • Xevo G2-XS QTof 4.4.0
  • Xevo G3 QTof 1.3.0
  • Vion IMS QTof 4.3.0

Acquisition

  • Sample Submission 2.1.0
  • Acquisition Method Editor 3.1.0
  • Laboratory Network Device 1.16.1

Data View & Processing

  • MAP Sequence 2.0.0
  • Peptide MAM 1.8.2
  • Intact Mass 1.9.0
  • Synthetic Library 2.0.0
  • Confirm Sequence 2.0.0

Instrument Drivers

  • ACQUITY RDa 3.4.0
  • Xevo G2-XS QTof 4.4.0
  • Xevo G3 QTof 1.3.0
  • Vion (not supported)

waters_connect for Bioprocessing

waters_connect for Bioprocessing

Bioprocess accurate mass applications for process (spent cell culture media) and product quality attribute monitoring including the Bioprocess Walk-Up Solution.

Acquisition

  • Sample Submission 2.1.0
  • Acquisition Method Editor 3.1.0
  • Laboratory Network Device 1.16.1

Data View & Processing

  • LC-MS Toolkit 1.11.0
  • UNIFI 3.6.0
  • Intact Mass 1.9.0

Instrument Drivers

  • ACQUITY RDa 3.4.0 only

waters_connect for Small Molecules

waters_connect for Small Molecules

Accurate mass-based solutions for screening of small molecules with versatile qualitative and quantitative analysis of compounds like pesticides, drugs of abuse, metabolites, impurities, extractables, and leachables.

Acquisition

  • UNIFI 3.6.0
  • Laboratory Network Device 1.16.1

Data View & Processing

  • UNIFI 3.6.0

Instrument Drivers

  • ACQUITY RDa 3.4.0
  • Xevo G2-XS QTof 4.4.0
  • Xevo G3 QTof 1.3.0
  • Vion IMS QTof 4.3.0

[new] = latest application release.

Configurations

This section provides an overview on supported operating systems, maximum number of instrument systems in a Network install and ACQUITY pumps, detectors, sample managers, column compartments available in waters_connect 3.2.0 LTS.

Operating System Support for Workstation Installs

Operating System Support for Workstation Installs

Operating System
Windows

Requirements

  • Windows Defender must be set to Off
  • OS language: English (US), Japanese (Japan).
  • Windows images provided with waters_connect PCs include Windows IoT Enterprise licensing which enables extended support on the operating system end of service over the standard edition. View more information on Windows releases.

Versions Supported
Workstation PC

  • Windows 10 Enterprise IoT LTSC 2021 edition (version 21H2)
  • Windows 10 Pro version 22H2

Operating System Support for Network Installs

Operating System Support for Network Installs

Operating System
Windows

Requirements

  • Windows Defender must be set to Off
  • OS language: English (US), Japanese (Japan)
  • Windows images provided with waters_connect PCs include Windows IoT Enterprise licensing which enables extended support on the operating system end of service over the standard edition. View more information on Windows releases.

Versions Supported

Server PC

  • Windows Server 2019 Standard

LND PC

  • Windows 10 Enterprise IoT LTSC 2021 edition (version 21H2)
  • Windows 10 Pro version 22H2

Client PC

  • Windows 10 Enterprise IoT LTSC 2021 edition (version 21H2)
  • Windows 10 Pro version 22H2

Mass spectrometry instruments supported on a single waters_connect Network deployment

Mass spectrometry instruments supported on a single waters_connect Network deployment

Instrument Type

Instrument Type

Instrument Type

Instrument Type

Instrument Type

Instrument Type

Instrument

Total Number of Systems

Recommended Number of Client PCs

Recommended Number of Users

Tof

Tof

Tof

Tof

Tof

Tof

  • ACQUITY RDa
  • BioAccord LCMS system 
  • Mix of Tof

up to 6

up to 6

  • up to 6 (concurrent)
  • up to 25 (active software accounts)

QTof

QTof

QTof

QTof

QTof

QTof

  • Xevo G2-XS QTof
  • Xevo G3 QTof
  • Vion IMS QTof
  • Mix of Tof and QTof
  • (Xevo MRT not supported)

up to 4

up to 4

  • up to 4 (concurrent)
  • up to 25 (active software accounts)

Tof & QTof

Tof & QTof

Tof & QTof

Tof & QTof

Tof & QTof

Tof & QTof

  • Mix of Tof and QTof
  • (Xevo MRT not supported)

up to 4

up to 4

  • up to 4 (concurrent)
  • up to 25 (active software accounts)

TQ

TQ

TQ

TQ

TQ

TQ

  • Xevo TQ-S cronos
  • Xevo TQ-S micro
  • Xevo TQ-XS 
  • Xevo TQ Absolute
  • Mix of Quads 

up to 5

up to 5

  • up to 10 (concurrent)
  • up to 25 (active software accounts)

TQ, Tof, & QTof

TQ, Tof, & QTof

TQ, Tof, & QTof

TQ, Tof, & QTof

TQ, Tof, & QTof

TQ, Tof, & QTof

  • Mix of Quads
  • QTofs/Tofs

up to 6 in the following combos:

  • up to 3 TQ + up to 3 QTof

  • up to 4 TQ + up to 2 QTof

  • up to 3 TQ + up to 2 QTof + 1 Tof

  • up to 3 TQ + 1 QTof + 2 Tof

  • up to 3 TQ + up to 3 Tof

up to 6

  • up to 6 (concurrent)
  • up to 25 (active software accounts)

ACQUITY Instrument Systems (such as pumps, detectors, sample managers, column compartments) supported by waters_connect driver pack ACQUITY UPLC DP v3.7.0

ACQUITY Instrument Systems (such as pumps, detectors, sample managers, column compartments) supported by waters_connect driver pack ACQUITY UPLC DP v3.7.0

Note: ACQUITY modules firmware versions and more information are detailed in the ACQUITY UPLC drive pack release notes.


Microscale ACQUITY UPLC Systems

Microscale ACQUITY UPLC Systems

ACQUITY UPLC M-Class

ACQUITY UPLC M-Class

UPLC Configuration

  • uBinary Solvent Manager
  • uSample Manager-Fixed Loop
  • Auxillary Solvent Manager
  • Trap Valve Manager

Acquisition Apps

  • Sample Submission

Supported MS Instruments

  • Xevo G3 QTof with NanoLockSpray and low-flow ESI probe
  • Xevo G2-XS QTof with low-flow ESI probe only 

Analytical ACQUITY UPLC Systems

Analytical ACQUITY UPLC Systems

ACQUITY Premier/ACQUITY H-Class Binary Series (15,000 PSI limited systems)

ACQUITY Premier/ACQUITY H-Class Binary Series (15,000 PSI limited systems)

UPLC Configuration

  • Binary Solvent Manager (BSM)
  • Sample Manager - Flow Through Needle (SM-FTN)
  • Column Heater (CH-A)
  • Column Manager (CM-A/CM-Aux)
    • Note: with Sample Submission up to 2 CM-Aux units using 6 columns

Acquisition Apps

  • Sample Submission (S)
  • UNIFI (U)

Supported MS Instruments

  • Xevo TQ-S cronos (S)
  • Xevo TQ-S micro (S)
  • Xevo TQ-XS (S)
  • Xevo TQ Absolute (S)
  • BioAccord (S & U)
  • ACQUITY RDa (U)
  • Xevo G2-XS QTof (S & U)
  • Xevo G3 QTof (S & U)
  • Vion IMS QTof (U)

ACQUITY Premier/ACQUITY H-Class Quaternary Series (15,000 PSI limited systems)

ACQUITY Premier/ACQUITY H-Class Quaternary Series (15,000 PSI limited systems)

UPLC Configuration

  • Quaternary Solvent Manager (QSM)
  • Sample Manager - Flow Through Needle (SM-FTN)
  • Column Heater (CH-A)
  • Column Manager (CM-A/CM-Aux)
    • Note: with sample Submission up to 2 CM-Aux units using 6 columns and Solvent Select Valve.

Acquisition Apps

  • Sample Submission (S)
  • UNIFI (U)

Supported MS Instruments

  • Xevo TQ-S cronos (S)
  • Xevo TQ-S micro (S) 
  • Xevo TQ-XS (S)
  • Xevo TQ Absolute (S)
  • BioAccord (S & U)
  • ACQUITY RDa (U)
  • Xevo G2-XS QTof (S & U)
  • Xevo G3 QTof (S & U)
  • Vion IMS QTof (U)

ACQUITY UPLC I-Class Plus Series (18,000 PSI limited systems)

ACQUITY UPLC I-Class Plus Series (18,000 PSI limited systems)

UPLC Configuration

  • Solvent Manager (BSM)
  • Sample Manager - Flow Through Needle (SM-FTN)
  • Sample Manager – Fixed Loop (SM-FL)
  • Column Heater (CH-A)
  • Column Manager (CM-A)

Acquisition Apps

  • Sample Submission (S)
  • UNIFI (U)

Supported MS Instruments

  • Xevo TQ-S cronos (S)
  • Xevo TQ-S micro (S) 
  • Xevo TQ-XS (S)
  • Xevo TQ Absolute (S)
  • BioAccord (S & U)
  • ACQUITY RDa (U)
  • Xevo G2-XS QTof (S & U)
  • Xevo G3 QTof (S & U)
  • Vion IMS QTof (U)

ACQUITY UPLC Series (15,000 PSI limited systems)

ACQUITY UPLC Series (15,000 PSI limited systems)

UPLC Configuration

  • Binary Solvent Manager (BSM)
  • Sample Manager – Fixed Loop (SM-XY)
  • Column Heater HTCH
  • Column Manager CM/CHC

Acquisition Apps

  • UNIFI

Supported MS Instruments

  • ACQUITY RDa
  • Xevo G2-XS QTof

ACQUITY UPLC Tunable UV (TUV) Detector

ACQUITY UPLC Tunable UV (TUV) Detector

Acquisition Apps

  • Sample Submission (S)
  • UNIFI (U)

Supported MS Instruments

  • Xevo TQ-S cronos (S)
  • Xevo TQ-S micro (S) 
  • Xevo TQ-XS (S)
  • BioAccord (S & U)
  • ACQUITY RDa (U)
  • Xevo G2-XS QTof (S & U)
  • Xevo G3 QTof (S & U)
  • Vion IMS QTof (U)

ACQUITY UPLC Photodiode Array (PDA)/eLambda PDA Detector (1; 2)

ACQUITY UPLC Photodiode Array (PDA)/eLambda PDA Detector (1; 2)

Acquisition Apps

  • UNIFI

Supported MS Instruments

  • BioAccord
  • ACQUITY RDa
  • Xevo G2-XS QTof
  • Xevo G3 QTof
  • Vion IMS QTof

ACQUITY UPLC Fluorescence (FLR) Detector

ACQUITY UPLC Fluorescence (FLR) Detector

Acquisition Apps

  • UNIFI

Supported MS Instruments

  • BioAccord
  • ACQUITY RDa
  • Xevo G2-XS QTof
  • Xevo G3 QTof
  • Vion IMS QTof

ACQUITY Common Platform Sample Organizer (CPSO)

ACQUITY Common Platform Sample Organizer (CPSO)

Acquisition Apps

  • UNIFI

Supported MS Instruments

  • BioAccord
  • ACQUITY RDa
  • Xevo G2-XS QTof
  • Xevo G3 QTof
  • Vion IMS QTof

ACQUITY eSAT/IN Module

ACQUITY eSAT/IN Module

Acquisition Apps

  • UNIFI

Supported MS Instruments

  • BioAccord
  • ACQUITY RDa
  • Xevo G2-XS QTof
  • Xevo G3 QTof
  • Vion IMS QTof

Supporting Files

回到頁首 回到頁首