waters_connect 4.4.0 Release Overview
Introduction
This page provides an overview of the waters_connect 4.4.0 release, compatible waters_connect applications, instrument drivers and supported system configurations including liquid & gas chromatography modules, mass spectrometry instruments, and detectors. For more information on waters_connect release types and associated level of software support please visit waters_connect Releases Overview
Release Overview
Recommended Use
waters_connect Software helps you accelerate the time to outcomes with workflow solutions ranging from quantitative, biopharma, and accurate mass-based analyses helping you reach new levels of efficiency, precision, and confidence.
Key solutions available with this release are:
waters_connect for Quantitation | Quantitative analysis software available on our core Xevo tandem quadrupole family of mass spectrometers, enabling laboratories to process large sample batches quickly and easily, significantly reducing the time spent on data review. Maximize your productivity with a compliant-ready workflow for analytical methodologies ranging from PFAS to genotoxic impurity analysis.
waters_connect for Biopharma | Accurate mass applications for protein-based therapeutics, vaccines, and nucleic acid-based therapeutics including applications for bioprocessing (spent cell culture media and product titer) and product quality attribute monitoring.
waters_connect for Small Molecules | Accurate mass-based solutions for targeted and non-targeted screening of small molecules, offering versatile qualitative and quantitative analysis of compounds such as pesticides, drugs of abuse, metabolites, impurities, extractables and leachables, and identification of contaminants like polymers, PFAS, and PCBs in complex samples.
waters_connect for Data Readiness | Accurate mass-based metabolomics, lipidomics and metabolite identification solutions with integration with 3rd Party software (via .mzML and/or via API).
waters_connect for Charge Detection | Achieve precise mass measurement of challenging large and highly heterogeneous biologics up to 150 MDa including viral vectors, virus-like particles (VLPs), RNA, and protein complexes that were previously out of reach for mass characterization.
waters_connect for Imaging | MS Imaging with Xevo MRT only: generate molecular spatial information directly from surfaces with Mass Spectrometry Imaging (MSI). The integration of DESI XS with Xevo MRT MS enables high spatial resolution, label-free molecular imaging directly from sample surfaces with minimal preparation, offering highly sensitive MS Imaging at speeds of up to 100 Hz, with sub-ppm mass accuracy, making it ideal for applications in biomedical research, drug distribution studies, and forensic analysis.
Key Benefits
Base
waters_connect Base offering comprises of platform Services, utility tools and core applications such as Hub, Administration, Scientific Library for general system use.
Versions released
waters_connect 4.4.0 includes core services and applications such as Services 7.16.0, Administration 2.12.1 and Hub 4.3.1
Benefits
Key benefits in this kit include:
Enhanced customer infrastructure security and compatibility with modern AI‑driven antiviruses through the implementation of industry‑trusted security certificates in waters_connect.
Enhanced Quantitative and Accurate Mass workflows for unknown component identification through support for industry‑leading scientific libraries and databases including NIST/EPA/NIH EI-GC/MS Library 2023, NIST Standalone MS/MS Library 2023, HMDB 5.0.0 and LipidMAPS.
Acquisition Kit
waters_connect Acquisition Kit comprises of Sample Submission, Method Editor and Laboratory Network Device applications. This kit enables data acquisition with third party GC instruments and Waters instrument systems used with waters_connect Quantitative analysis software, such as Xevo TQ-S cronos, Xevo TQ-S micro, Xevo TQ-XS, Xevo TQ Absolute and Xevo TQ Absolute XR & accurate mass applications with Xevo G2-XS QTof, Xevo G3 QTof, Xevo MRT, Xevo CDMS, BioAccord LC-MS System and ACQUITY RDa detector.
Versions released
waters_connect 4.4.0 is compatible with Acquisition Kit 3.5.0
Acquisition Kit 3.5.0 is the latest release and includes waters_connect applications such as Sample Submission 2.10.0, Method Editor 4.6.0 and LND 1.26.0.
Benefits
Key Benefits in Acquisition Kit 3.5.0 include:
Enhanced customer infrastructure security and compatibility with modern AI‑driven antiviruses through the implementation of industry‑trusted security certificates in waters_connect Acquisition Kit.
Achieve expanded analytical depth and workflow flexibility using the Xevo MRT MS with new data acquisition methodology. SONAR Pulse is a data-independent acquisition mode that employs a stepping quadrupole for increased selectivity in discovery applications. This, in addition to the expansion of source ionization options via UniSpray, offers scientists greater flexibility and analyte coverage.
Improved flexibility and productivity when submitting samples by allowing users to assign a Normal or High priority flag to a batch which automatically determines its position in the queue.
Improved product quality and stability by resolving high‑impact issues related to sample sets entering an edit state during data buffering.
LC-MS Toolkit
waters_connect LC-MS Toolkit application enables data interrogation outside of the defined workflows and provides flexibility to the software that is needed for more advanced use.
Versions released
waters_connect 4.4.0 is compatible with LC-MS toolkit 1.19.0
Benefits
Key Benefits in LC-MS Toolkit 1.19.0 include:
Enhanced customer infrastructure security and compatibility with modern AI‑driven antiviruses through the implementation of industry‑trusted security certificates in waters_connect LC-MS ToolKit.
Achieve expanded analytical depth and workflow flexibility using the Xevo MRT MS with new real time data viewing and interrogations. SONAR Pulse is a data-independent acquisition mode that employs a stepping quadrupole for increased selectivity in discovery applications.
Expanding LC-MS ToolKit application capabilities with focus on usability and productivity enhancements including:
Enabling users to manually annotate plots in Compare mode.
Automatically generate MS and MSe spectra for integrated peaks in the Peak Table with Peak asymmetry calculation and improved RT identification for MRM data.
DDA improvements by displaying the RT of the Survey Scan in the DDA Switch Table and caching for performance improvements.
Data Conversion
The Data Convert application for waters_connect enables increased data compatibility with third-party software applications via conversion of Optical data, MS, MS/MS, DDA and MSE data into .mzML format.
Versions released
waters_connect 4.4.0 is compatible with Data Convert 4.0.0.
Benefits
Key benefits in this application include:
Improved data compatibility and workflow flexibility to boost interoperability and usability when converting analytical data to the generic .mzML format with support for:
PDA and TUV data.
HDMSE (ion mobility) data.
Aligned DIA
MRM data (Tandem Quad and Tof MRM)
MS Quan
waters_connect MS Quan application is a quantitative analysis software available on our core Xevo tandem quadrupole family of mass spectrometers. It enables routine small-molecule quantitation and accelerates quantitation data processing and review steps with exception-focused review and easy-to-view chromatogram windows for multiple samples.
Versions released
waters_connect 4.4.0 is compatible with MS Quan 2.5.2 & 2.6.0.
Benefits
Key Benefits in MS Quan 2.6.0 include:
MS Quan 2.6 now includes custom calculations providing the flexibility to define user specified calculations within processing methods to support analytical needs. This provides:
- Increased review speed as calculations run automatically and update in real-time with changes to the batch.
- Greater control of calculations by bringing external Excel calculations into compliance control with full audit and edit permission for calculations.
- Reduced Risk by removing the need for validated Excel sheets. Changes to the method are tracked and audited.
- Calculated values and results can be printed to pdf or exported to LIMS via csv or API.
Includes a new by injection pivot is available for the data summary page allowing customers to visualize the analytes in an injection when this is a more appropriate view of the data.
In addition, data export to csv can now be configured to integrate directly with downstream integration specifications.
Key Benefits in MS Quan 2.5.2 include:
Expanding MS Quan capabilities with a focus on processing efficiency, such as:
A new peak integration data pivot allowing customers to view all analytes per injection.
Configurable view of the data summary table to allow customers to include and interact with calibration curves and chromatograms in a single view. This Multi Panel view provides customers with the ability to re-integrate or update calibrations and view the data summary simultaneously.
New smart navigation shortcuts providing customers with seamless transitions between Peak Integration, Data Summary and Calibration Curve pages while maintaining context.
The calculation of peak asymmetry for system suitability injections to further to assist with Demonstrations of Capability as in EPA 537.1 and evaluation of chromatographic changes.
The calculation of peak widths to assist customers in the assessment of chromatographic performance. Values included in Data Summary table and all reporting formats.
Extension of S/N region visualization and updating for all sample types for customers applying non-pharmacopeia calculations, includes the option to include regions in pdf reports.
Processed results can now be exported as XML data. This is of particular benefit to customers wanting to integrate with LIMS systems requiring this format.
UNIFI
waters_connect UNIFI application enables the execution of accurate mass experiments ranging from Small Molecules to Biologics. Moreover, it provides access to core applications such as System Console, Device Management, Explorer, and Qualification for general system use.
Versions released
waters_connect 4.4.0 is compatible with UNIFI 3.17.0
Benefits
Key Benefits in UNIFI 3.17.0 include:
Enhanced customer infrastructure security and compatibility with modern AI‑driven antiviruses through the implementation of industry‑trusted security certificates in waters_connect UNIFI.
Improved product quality and stability by resolving high‑impact issue related to to properly lock and unlock methods used in their workflows, ensuring compliance with their SOP requirements.
Pattern Analysis
The waters_connect Pattern Analysis application increases data clarity in complex assays and enhances the confidence in identifying contaminants, such as polymers, PFAS and PCBs.
Versions released
waters_connect 4.4.0 is compatible with Pattern Analysis 1.1.0.
Benefits
Key Benefits in Pattern Analysis 1.1.0 include:
Ability to process MS data that has been acquired together with PDA data.
Introduce the ability to Create, Clone, Delete and Select Pattern Analysis methods.
Ability to specify a m/z range for data processing and detect monomer sequences based on the specified mass range.
Components can be banked and unbanked from the Component List table.
Enable library searching to be performed with respect to retention time in addition to mass.
Filtered components can be exported as a Pattern Analysis library.
Ability to change the default assignment when multiple targets are assigned to a component.
*Note: Application has not yet been validated with SONAR Pulse data types
Peptide MAM
waters_connect Peptide Multi-Attribute Monitoring (MAM) application enables monitoring of biopharmaceutical product quality attributes (PQA) at the peptide level.
Versions released
waters_connect 4.4.0 is compatible with Peptide MAM 1.8.3.
Benefits
Key Benefits in Peptide MAM 1.8.3 include:
General maintenance release
Defect fixes
Intact Mass
waters_connect Intact Mass application enables biologics mass confirmation and purity determination of oligonucleotides, peptides, protein and conjugates.
Versions released
waters_connect 4.4.0 is compatible with Intact Mass 1.9.0.
Benefits
Key Benefits in Intact Mass 1.9.0 include:
Automated Calculations of DAR and Drug Distribution for Conjugated Molecule Analysis - users can now deploy a BioAccord System, Xevo G3 QTof, or Xevo MRT QTof to analyze conjugated molecules, specifying the conjugate and its mass in the Intact Mass data processing parameters, and have the calculation of Drug Antibody Ratio and distribution of conjugate forms automatically performed from the acquired data.
Controls for manual adjustments of chromatographic integration - users can now manually adjust chromatographic peak integration and associated peak identification results and use those reintegrated peaks to direct the processing of mass spectral data.
Sample List Entry of Chemical Formula - users can now specify a ‘Chemical formula for deconvolution’ that will be used to refine the deconvolution isotope model, improving deconvolution mass accuracy and quantification.
Updated Sample List Column ‘Expected Masses’ changed to ‘Expected Masses and/or Chemical Formulas’ - users now can enter targets as numeric masses, as chemical formulas, or a mixture of both.
New Method option within ‘Specify calculation parameters’, allowing the user more control over the ‘Main Peak Retention Time Window’ to improve main peak identification in Optical Only and Variant Analysis workflows
Bioprocessing workflow: Additional sample list columns for Time Point and Dilution Factor that facilitates processing time series trending data (in bioprocess monitor or in third party solutions) and dilution factor to enable clearer results visualization and trending.
Application compatibility with data management.
Synthetic Library
waters_connect Synthetic Library supports the Confirm Sequence and Map Sequence applications for oligo sequencing and mapping workflows.
Versions released
waters_connect 4.4.0 is compatible with Synthetic Library 2.0.
Benefits
Key Benefits in Synthetic Library 2.0 include:
Support for oligo mapping workflow - new enzymes and polynucleotides sections
Multiple library support including user access controls
CONFIRM Sequence
waters_connect Confirm Sequence enables streamlined oligonucleotide sequence confirmation and impurity characterization workflow.
Versions released
waters_connect 4.4.0 is compatible with Confirm Sequence 2.1.1.
Benefits
Key Benefits in Confirm Sequence 2.1.1 include:
- General maintenance release
- Defect fixes
Map Sequence
waters_connect Map Sequence enables accurate mass mapping of digested oligonucleotides.
Versions released
waters_connect 4.4.0 is compatible with Map Sequence 2.0.
Benefits
Key Benefits in Map Sequence 2.0 include:
Supported by Synthetic Library for sequence entry and experimental planning
Oligo mapping and sequence confirmation using LCMSE precursor and fragment data
Interactive annotated chromatogram
Interactive coverage map for simple visualization of sequence coverage and navigation to supporting data
Drill-down to fragment analysis
Dynamic pass-fail filtering and acceptance criteria for investigation and curation of results
Integrated reporting
Bioprocess Monitor
The waters_connect Bioprocess Monitor application enables routine, in-process monitoring of spent media components and product titer via absolute and relative quantification using LC-Optical Detection, LC-MS & LC-Optical/MS techniques.
Versions released
waters_connect 4.4.0 is compatible with Bioprocess Monitor 1.2.0
Benefits
Key benefits in Bioprocess Monitor 1.2.0 include:
- Analytical Capability - Expanded detection with FLR support to enhance sensitivity and confidence in measurements
- Compliance - Support for GMP environments with role-based restrictions and action comments
- Connectivity - Scalable deployment enabled through waters_connect network support
- Global Access - Improved usability with Japanese localisation
CDMS Toolkit
The waters_connect CDMS Toolkit application empowers customers to unlock the full potential of Xevo CDMS by enabling access to real-time data acquisition, native analysis, and advanced visualization, streamlining workflows and accelerating insights into large, complex biomolecules.
Versions released
waters_connect 4.4.0 is compatible with CDMS Toolkit 1.1.0.
Benefits
Key benefits in CDMS Toolkit 1.1.0 include:
Enables native analysis of large protein assemblies and multi-subunit complexes, including tools for assessing molecular weight, purity, and heterogeneity.
Real-time display of mass, mass-to-charge, and charge spectra, along with corresponding 2-dimensional heatmaps.
Raw data review for pre-acquired and live acquisition.
Relative quantitation analysis to determine quantities of user defined targets.
Application compatibility with data management.
Compliant workflow with support for audit reasons, and UNIFI report sign off.
Japanese localisation.
MS Imaging
The MS Imaging application with waters_connect control enables customers to generate molecular spatial information directly from surfaces using the DESI XS Xevo MRT MS system solution. The integration of DESI XS with Xevo MRT MS enables high spatial resolution, label-free molecular imaging directly from sample surfaces with minimal preparation, offering highly sensitive MS Imaging at speeds of up to 100 Hz, with sub-ppm mass accuracy, making it ideal for applications in biomedical research, drug distribution studies, and forensic analysis.
Versions released
waters_connect 4.4.0 is compatible with MS Imaging 1.0.0 in combination with Xevo MRT v1.6.0.
Benefits
Key benefits in MS Imaging 1.0.0 include:
Application specific tuning parameters for MS Imaging.
Control for DESI XS, ACQUITY DESI uBSM and Xevo MRT MS under waters_connect.
Data generation for processing with Waters HDI 1.9.
Microscope mode workflow for targeted high spatial resolution MS Imaging as well as targeted MS/MS.
Export as imzML or .RAW for 3rd party processing (e.g. Scils or Lipostar MSI).
Applications
waters_connect for Quantitation
Quantitative analysis software available on our core Xevo tandem quadrupole family of mass spectrometers, enabling laboratories to process large sample batches quickly and easily, significantly reducing the time spent on data review. Maximize your productivity with a compliant-ready workflow for analytical methodologies ranging from PFAS to genotoxic impurity analysis.
Acquisition
- Sample Submission 2.10.0 [new]
- Acquisition Method Editor 4.6.0 [new]
- Laboratory Network Device 1.26.0 [new]
- Cloud Edge software for System Monitoring (latest available)
Data View & Processing
- LC-MS Toolkit 1.19.0 [new]
- MS Quan 2.5.2
- MS Quan 2.6.0 [new]
Instrument Drivers
- ACQUITY UPLC DP 3.9.0
- 3rd Party ICF 3.1.0
- Xevo TQ-S cronos 2.1.0
- Xevo TQ-S micro 2.1.0
- Xevo TQ-XS 2.1.0
- Xevo TQ Absolute 2.1.0
- Xevo TQ Absolute XR 2.1.0
Xevo TQ-S cronos 2.2.0 [new]
Xevo TQ-S micro 2.2.0 [new]
Xevo TQ-XS 2.2.0 [new]
Xevo TQ Absolute 2.2.0 [new]
Xevo TQ Absolute XR 2.2.0 [new]
waters_connect for Biopharma
Biopharmaceutical accurate mass applications for protein-based therapeutics, vaccines, and nucleic acid-based therapeutics.
Acquisition
- Sample Submission 2.10.0 [new]
Acquisition Method Editor 4.6.0 [new]
Laboratory Network Device 1.26.0 [new]
Cloud Edge software for System Monitoring (latest available)
Data View & Processing
- LC-MS Toolkit 1.19.0 [new]
UNIFI 3.17.0 [new]
Data Convert 4.0.0
Peptide MAM 1.8.3 [new]
Intact Mass 1.9.0
- Bioprocess Monitor 1.2.0 [new]
Confirm Sequence 2.1.1 [new]
- Synthetic Library 2.0.0
Map Sequence 2.0.0
Instrument Drivers
ACQUITY UPLC DP 3.9.0
3rd Party ICF 3.1.0
BioAccord 3.5.0
Xevo G2-XS QTof 4.4.0
Xevo G3 QTof 1.4.0
Xevo MRT 1.6.0 [new]
Vion IMS QTof 4.3.0
waters_connect for Bioprocessing
Bioprocess accurate mass applications for process (spent cell culture media) and product quality attribute monitoring with the BioAccord LC-MS system and Bioprocess Walk-Up Solutions.
Acquisition
- Sample Submission 2.10.0 [new]
Acquisition Method Editor 4.6.0 [new]
Laboratory Network Device 1.26.0 [new]
Cloud Edge software for System Monitoring (latest available)
Data View & Processing
LC-MS Toolkit 1.19.0 [new]
UNIFI 3.17.0 [new]
Peptide MAM 1.8.3 [new]
Intact Mass 1.9.0
- Bioprocess Monitor 1.2.0 [new]
Instrument Drivers
ACQUITY UPLC DP 3.9.0
BioAccord 3.5.0
waters_connect for CDMS
Achieve precise mass measurement of challenging large and highly heterogeneous biologics including viral vectors, virus-like particles (VLPs), RNA, and protein complexes that were previously out of reach for mass characterization.
Acquisition
Sample Submission 2.10.0 [new]
Acquisition Method Editor 4.6.0 [new]
Laboratory Network Device 1.26.0 [new]
Data View & Processing
CDMS Toolkit 1.1.0
Instrument Drivers
Xevo CDMS 1.0.0
waters_connect for Small Molecules
Accurate mass-based solutions for targeted and non-targeted screening of small molecules, offering versatile qualitative and quantitative analysis of compounds such as pesticides, drugs of abuse, metabolites, impurities, extractables and leachables, and identification of contaminants like polymers, PFAS, and PCBs in complex samples.
Acquisition
- Sample Submission 2.10.0 [new]
Acquisition Method Editor 4.6.0 [new]
Laboratory Network Device 1.26.0 [new]
Cloud Edge software for System Monitoring (latest available)
Data View & Processing
LC-MS Toolkit 1.19.0 [new]
UNIFI 3.17.0 [new]
Pattern Analysis 1.1.0
Data Convert 4.0.0
Instrument Drivers
ACQUITY UPLC DP 3.9.0
3rd Party ICF 3.1.0
ACQUITY RDa 3.5.0
Xevo G2-XS QTof 4.4.0
Xevo G3 QTof 1.4.0
Xevo MRT 1.6.0 [new]
Vion IMS QTof 4.3.0
waters_connect for Data Readiness
Accurate mass-based metabolomics, lipidomics and metabolite identification solutions with integration with 3rd Party software (via .mzML and/or via API)
Acquisition
- Sample Submission 2.10.0 [new]
Acquisition Method Editor 4.6.0 [new]
Laboratory Network Device 1.26.0 [new]
Cloud Edge software for System Monitoring (latest available)
Data View & Processing
- LC-MS Toolkit 1.19.0 [new]
UNIFI 3.17.0 [new]
Data Convert 4.0.0
Instrument Drivers
ACQUITY UPLC DP 3.9.0
ACQUITY RDa 3.5.0
Xevo G2-XS QTof 4.4.0
Xevo G3 QTof 1.4.0
Xevo MRT 1.6.0 [new]
[new] = latest application release.
waters_connect for Imaging
Generate molecular spatial information directly from surfaces with Mass Spectrometry Imaging and the powerful integration of DESI XS with Xevo MRT MS.
Acquisition
MS Imaging 1.0
Sample Submission 2.10.0 [new]
Acquisition Method Editor 4.6.0 [new]
Laboratory Network Device 1.26.0 [new]
Data View & Processing
Waters HDI 1.9.0
Instrument Drivers
Xevo MRT 1.6.0 [new]
Configurations
This section provides an overview on supported operating systems, maximum number of instrument systems in a Network install and inlets modules such as pumps, detectors, sample managers, column compartments available in waters_connect 4.4.0.
Operating System Support for Workstation Installs
Operating System
Windows
Requirements
OS language: English (US), Japanese (Japan).
Windows images provided with waters_connect PCs include Windows IoT Enterprise licensing which enables extended support on the operating system end of service over the standard edition. For more information on Windows releases visit https://learn.microsoft.com/en-us/windows/release-health/
Versions Supported
Workstation PC
- Windows 10 Enterprise LTSC 2021 edition (version 21H2)
- Windows 10 Enterprise IoT LTSC 2021 edition (version 21H2)
- Windows 11 Enterprise LTSC 2024 edition (version 24H2)
- Windows 11 Enterprise IoT LTSC 2024 edition (version 24H2)
- Windows 11 Pro version 24H2
Operating System Support for Network Installs
Operating System
Windows
Requirements
- OS language: English (US), Japanese (Japan). Note: for Client PCs only the software deployment is supported on European and Japanese language versions of Windows. However, Hub is displayed in English (US) or Japanese (Japan) only.
- Windows images provided with waters_connect PCs include Windows IoT Enterprise licensing which enables extended support on the operating system end of service over the standard edition. For more information on Windows releases visit https://learn.microsoft.com/en-us/windows/release-health
Note: Windows 11 and Windows Server 2025 introduce updates to underlying math libraries, floating-point handling, and processor optimizations that can lead to slight differences in calculated values compared to previous Windows versions.
Versions Supported
Server PC
- Windows Server 2025 Standard Edition
- Windows Server 2019 Standard Edition
Note 1: Mainstream support for Windows Server 2019 Standard ended, recommend to adopt the latest Windows Server OS.
Note 2: OS In-upgrade is supported.
LND PC
Windows 10 Enterprise LTSC 2021 Edition (version 21H2)
Windows 10 Enterprise IoT LTSC 2021 Edition (version 21H2)
Windows 11 Enterprise IoT LTSC 2024 Edition (version 24H2) [new]
Client PC
- Windows 10 Enterprise LTSC 2021 Edition (version 21H2)
- Windows 10 Enterprise IoT LTSC 2021 Edition (version 21H2)
- Windows 11 Enterprise LTSC 2024 Edition (version 24H2)
- Windows 11 Pro version (24H2)
- Windows Server 2025 Standard Edition
- Windows Server 2019 Standard Edition
Note: Windows 11 and Windows Server 2025 introduce updates to underlying math libraries, floating-point handling, and processor optimizations that can lead to slight differences in calculated values compared to previous Windows versions.
Mass spectrometry instruments supported on a single waters_connect network deployment
|
|
|
|
|
|
|---|---|---|---|---|
Instrument Type |
Instrument Type |
Instrument Type |
Instrument Type |
Instrument Type |
Instrument Type |
Instrument |
Total Number of Systems |
Recommended Number of Client PCs |
Recommended Number of Users |
Tof |
Tof |
Tof |
Tof |
Tof |
Tof |
|
up to 6 |
up to 6 |
|
QTof |
QTof |
QTof |
QTof |
QTof |
QTof |
|
up to 4 |
up to 4 |
|
|
QTof |
QTof |
QTof |
QTof |
QTof |
|
QTof |
Xevo MRT |
up to 2 |
up to 4 |
|
Tof & QTof |
Tof & QTof |
Tof & QTof |
Tof & QTof |
Tof & QTof |
Tof & QTof |
|
up to 4 in the following combos:
|
up to 4 |
|
TQ |
TQ |
TQ |
TQ |
TQ |
TQ |
|
up to 9 |
up to 9 |
|
|
TQ |
TQ |
TQ |
TQ |
TQ |
|
TQ |
Mix of Quads & QTofs/Tofs (excluding Xevo MRT) |
up to 6 in the following combos:
|
up to 6 |
|
TQ, Tof, & QTof |
TQ, Tof, & QTof |
TQ, Tof, & QTof |
TQ, Tof, & QTof |
TQ, Tof, & QTof |
TQ, Tof, & QTof |
|
up to 5 in the following combos:
|
up to 5 |
|
Instrument systems modules supported (such as pumps, detectors, sample managers, column compartments)
Note: Full information on new features and quality improvements and more is available in the appropriate instrument model release notes at waters.com
Gas Chromatography systems
Agilent GC system
GC Configuration
Agilent 8890 GC
Agilent 7693A Automatic Liquid Sampler
CTC PAL3 Series 2 Autosampler
Acquisition Apps
- Sample Submission
Supported MS Instruments
Xevo G3 QTof with Waters Atmospheric Pressure Gas Chromatography (APGC) source
Xevo TQ Absolute with Waters APGC source
Xevo TQ Absolute XR with Waters APGC source
Microscale ACQUITY UPLC systems
ACQUITY UPLC M-Class
UPLC Configuration
uBinary Solvent Manager
uSample Manager-Fixed Loop
Auxillary Solvent Manager
Trap Valve Manager
Acquisition Apps
- Sample Submission
Supported MS Instruments
Xevo MRT with NanoLockSpray and low-flow ESI probe
Xevo G3 QTof with NanoLockSpray and low-flow ESI probe
Xevo G2-XS QTof with low-flow ESI probe only
Analytical ACQUITY UPLC systems
ACQUITY Premier/ACQUITY H-Class Binary Series (15,000 PSI limited systems)
UPLC Configuration
Binary Solvent Manager (BSM)
Sample Manager - Flow Through Needle (SM-FTN)
Sample Manager – Fixed Loop (SM-FL)
Column Heater (CH-A)
Column Manager CM/CHC 30cm
Column Manager (CM-A/CM-Aux)*
*Note: with Sample Submission up to 2 CM-Aux units using 6 columns
Acquisition Apps
- Sample Submission (S)
- UNIFI (U)
Supported MS Instruments
Xevo TQ-S cronos (S)
Xevo TQ-S micro (S)
Xevo TQ-XS (S)
Xevo TQ Absolute (S)
Xevo TQ Absolute XR (S)
BioAccord (S & U)
ACQUITY RDa (U)
Xevo G2-XS QTof (S & U)
Xevo G3 QTof (S & U)
Vion IMS QTof (U)
Xevo MRT (S)
ACQUITY Premier/ACQUITY H-Class Quaternary Series (15,000 PSI limited systems)
UPLC Configuration
Quaternary Solvent Manager (QSM)
Sample Manager - Flow Through Needle (SM-FTN)
Sample Manager – Fixed Loop (SM-FL)
Column Heater (CH-A)
Column Manager CM/CHC 30cm
Column Manager (CM-A/CM-Aux)*
*Note: with sample Submission up to 2 CM-Aux units using 6 columns and Solvent Select Valve.
Acquisition Apps
- Sample Submission (S)
- UNIFI (U)
Supported MS Instruments
Xevo TQ-S cronos (S)
Xevo TQ-S micro (S)
Xevo TQ-XS (S)
Xevo TQ Absolute (S)
Xevo TQ Absolute XR (S)
BioAccord (S & U)
ACQUITY RDa (U)
Xevo G2-XS QTof (S & U)
Xevo G3 QTof (S & U)
Vion IMS QTof (U)
Xevo MRT (S)
ACQUITY UPLC I-Class Plus Series (18,000 PSI limited systems)
UPLC Configuration
Solvent Manager (BSM)
Sample Manager - Flow Through Needle (SM-FTN)
Sample Manager – Fixed Loop (SM-FL)
Column Heater (CH-A)
Column Manager (CM-A)
Acquisition Apps
- Sample Submission (S)
- UNIFI (U)
Supported MS Instruments
Xevo TQ-S cronos (S)
Xevo TQ-S micro (S)
Xevo TQ-XS (S)
Xevo TQ Absolute (S)
Xevo TQ Absolute XR (S)
BioAccord (S & U)
ACQUITY RDa (U)
Xevo G2-XS QTof (S & U)
Xevo G3 QTof (S & U)
Vion IMS QTof (U)
Xevo MRT (S)
ACQUITY UPLC Series (15,000 PSI limited systems)
UPLC Configuration
Binary Solvent Manager (BSM)
Sample Manager – Fixed Loop (SM-XY)
Column Heater HTCH
Column Manager CM/CHC
Acquisition Apps
- UNIFI
Supported MS Instruments
- ACQUITY RDa
- Xevo G2-XS QTof
ACQUITY UPLC Tunable UV (TUV) Detector
Acquisition Apps
- Sample Submission (S)
- UNIFI (U)
Supported MS Instruments
Xevo TQ-S cronos (S)
Xevo TQ-S micro (S)
Xevo TQ-XS (S)
Xevo TQ Absolute (S)
Xevo TQ Absolute XR (S)
BioAccord (S & U)
ACQUITY RDa (U)
Xevo G2-XS QTof (S & U)
Xevo G3 QTof (S & U)
Vion IMS QTof (U)
Xevo MRT (S)
ACQUITY UPLC Photodiode Array (PDA)/eLambda PDA Detector (1; 2)
Acquisition Apps
- Sample Submission (S)
- UNIFI (U)
Supported MS Instruments
Xevo TQ-S cronos (S)
Xevo TQ-S micro (S)
Xevo TQ-XS (S)
Xevo TQ Absolute (S)
Xevo TQ Absolute XR (S)
BioAccord (S & U)
ACQUITY RDa (U)
Xevo G2-XS QTof (S & U)
Xevo G3 QTof (S & U)
Vion IMS QTof (U)
Xevo MRT (S)
ACQUITY UPLC Fluorescence (FLR) Detector
Acquisition Apps
Sample Submission (S)
UNIFI (U)
Supported MS Instruments
- Xevo TQ-S cronos (S)
Xevo TQ-S micro (S)
Xevo TQ-XS (S)
Xevo TQ Absolute (S)
Xevo TQ Absolute XR (S)
BioAccord (S & U)
ACQUITY RDa (U)
Xevo G2-XS QTof (S & U)
Xevo G3 QTof (S & U)
Vion IMS QTof (U)
Xevo MRT (S)
ACQUITY Common Platform Sample Organizer (CPSO)
Acquisition Apps
- Sample Submission (S)
- UNIFI (U)
Supported MS Instruments
Xevo TQ-S cronos (S)
Xevo TQ-S micro (S)
Xevo TQ-XS (S)
Xevo TQ Absolute (S)
Xevo TQ Absolute XR (S)
BioAccord (S & U)
ACQUITY RDa (U)
Xevo G2-XS QTof (S & U)
Xevo G3 QTof (S & U)
Vion IMS QTof (U)
Xevo MRT (S)
ACQUITY eSAT/IN Module
Acquisition Apps
- UNIFI
Supported MS Instruments
BioAccord
ACQUITY RDa
Xevo G2-XS QTof
Xevo G3 QTof
Vion IMS QTof
DESI XS Module
Acquisition Apps
MS Imaging
Supported MS Instruments
Xevo MRT MS