waters_connect 3.6.0 Release Overview

waters_connect 3.6.0 Release Overview

Introduction

Introduction

This page provides an overview of the waters_connect 3.6.0 release, compatible waters_connect applications, instrument drivers and supported system configurations including liquid chromatography modules, mass spectrometry instruments, and detectors. For more information on waters_connect release types and associated level of software support please visit waters_connect Releases Overview.

Release Overview

Recommended Use

waters_connect helps you accelerate the time to outcomes with workflow solutions ranging from quantitative, biopharma, and accurate mass-based analyses helping you reach new levels of efficiency, precision, and confidence.

Key Solutions Available with this Release

  • waters_connect for Biopharma — Accurate mass applications for protein-based therapeutics, vaccines, and nucleic acid-based therapeutics including applications for bioprocessing (spent cell culture media) and product quality attribute monitoring.
  • waters_connect for Small Molecules — Accurate mass-based solutions for screening of small molecules.
  • waters_connect for Research & Routine — Accurate mass-based metabolomics, lipidomics and metabolite identification solutions with integration with 3rd Party software (via .mzML and/or via API).

Key Benefits

Key Benefits

Base Kit

Base Kit

Comprises platform components and core applications such as Hub, Administration, System Console, Device Management, Explorer, Qualification for general system use.

Key benefits in this release include:

  • waters_connect Base Kit comprises of platform services, utility tools and core applications such as Hub, Administration, Scientific Library for general system use
  • Improved lab automation and integration with 3rd party software via new endpoints in the waters_connect Application Programming Interface (API). Benefit from a greater API connectivity and performance such as:
    • access to lock mass corrected data, continuum spectra, centroided spectra, combined spectra, extracted mass chromatograms;
    • direct data transfer to Mass Analytica software suite for data generated in waters_connect with instruments such as Xevo G3 QTof and Xevo MRT;
    • build workflows around method draft lifecycles;
    • search common fields for Name, Description, Version, CreatedDateTime, ModifiedDateTime, Folder, TypeId,  CreatedByUsername,  ModifiedByUsername, State;
    • get information about the backup jobs;
    • support registered third party browser apps previously blocked by the browser CORS setting.

LC-MS Toolkit

LC-MS Toolkit

LC-MS Toolkit enables data interrogation outside of the defined workflows and provides flexibility to the software that is needed for more advanced use.

Key benefits in this release include:

  • Increased data clarity and speed to results with data view and interrogation enhancements in the LC-MS Toolkit application, such as:
    • automatic calculation and annotation for the mass resolution of an ion;
    • base peak mass annotations in chromatograms;
    • view and interrogate Xevo MRT data;
    • perform multiple extracted ion chromatograms from pre-saved groups of analytes;
  • Increased productivity by generating LC-MS Toolkit sessions in real time and post acquisition at the sample list level from within the submission application.

Acquisition Kit

Acquisition Kit

waters_connect Acquisition Kit comprises of Sample Submission, Method Editor and Laboratory Network Device enable data acquisition with Waters instrument systems used for accurate mass applications with Xevo G2-XS QTof, Xevo G3 QTof, Xevo MRT and BioAccord System.

Key benefits in this release include:

  • Increased lab productivity and throughput with the introduction of support for the Xevo MRT instrument within the Sample Submission and Method Editor applications in a waters_connect workstation install;
  • Improved productivity and usability at the point of sample submission with the ability to select injections in the sample list and directly interrogate data in LC-MS Toolkit sessions from either injections being acquired, and from samples acquired completed.

Data Convert

Data Convert

waters_connect Data Convert enables increased data compatibility with third-party software applications via conversion of MS, MS/MS, DDA and MSE data into .mzML format.

Key benefits in this release include:

  • Improved productivity when submitting samples with Xevo MRT, Xevo G2-XS QTof and ACQUITY RDa by converting acquired data to generic file format (.mzML) in real-time, ensuring immediate availability for third-party software use.

UNIFI

UNIFI

waters_connect UNIFI enables the execution of accurate mass experiments ranging from Small Molecules to Biologics. Moreover, it provides access to core applications such as System Console, Device Management, Explorer, and Qualification for general system use.

Key benefits in this release include:

  • Increased usability and productivity for the Small Molecules and Biologics workflows by automating data acquisition in sample submission and data processing in UNIFI when using Xevo MRT, Xevo G3 QTof, Xevo G2-XS QTof, and ACQUITY RDa;
  • Faster time to results and enhanced data clarity when using the UNIFI application workflows with Xevo MRT instrument. Benefit from the high mass resolving power and sub-ppm mass accuracy even at the fastest acquisition rates and leverage the power of confident identification of analytes across a range of samples and matrices with the UNIFI Small Molecules and UNIFI Biologics workflows;
  • Increased lab productivity with the introduction of support on waters_connect short term releases for Vion IMS QTof instrument within the UNIFI application for workstation and network installs.

Peptide MAM

Peptide MAM

waters_connect Peptide Multi-Attribute Method (MAM) enables monitoring of biopharmaceutical product quality attributes (PQA) at the peptide level.

Versions released

waters_connect 3.6 is compatible with Peptide MAM 1.8.2

Benefits

Key Benefits in Peptide MAM 1.8.2 include:

  • General maintenance release

  • Defect fixes

Key benefits in Peptide MAM 1.8.0 release include:

  • An Application Programming Interface (API) is now available that supports creation of analyses and retrieval of results by third party informatics tools.
  • Enhanced processing of data containing higher mass peptides by an Improved Monoisotopic Peak Detection (IMPD) routine, which supports detection of a lower intensity or missing monoisotopic peak.
  • Localization into Japanese

Key benefits in Peptide MAM 1.8.1 release include:

  • Support for PDA optical detectors. In addition to TUV, users can now view the optical channels from the PDA detector.
  • Support for Sample Organizer, allowing up to19 microtiter plates, or, 9 intermediate height plates, or, 6 deep-well plates. Increasing the potential throughput for Peptide MAM users.

Intact Mass

Intact Mass

waters_connect Intact Mass enables biologics mass confirmation and purity determination of oligonucleotides, peptides, protein and conjugates.

Versions released

waters_connect 3.6 is compatible with Intact Mass 1.9.

Benefits

Key benefits in Intact Mass 1.9 include:

  • Automated Calculations of DAR and Drug Distribution for Conjugated Molecule Analysis - Users can now deploy a BioAccord System, Xevo G3 QTof, or Xevo MRT QTof to analyze conjugated molecules, specifying the conjugate and its mass in the INTACT Mass data processing parameters, and have the calculation of Drug Antibody Ratio and distribution of conjugate forms automatically performed from the acquired data.

  • Controls for manual adjustments of chromatographic integration - Users can now manually adjust chromatographic peak integration and associated peak identification results and use those reintegrated peaks to direct the processing of mass spectral data.

  • Sample List Entry of Chemical Formula - User can now specify a ‘Chemical formula for deconvolution’ that will be used to refine the deconvolution isotope model, improving deconvolution mass accuracy and quantification.

  • Updated Sample List Column ‘Expected Masses’ changed to ‘Expected Masses and/or Chemical Formulas’: Users now can enter targets as numeric masses, as chemical formulas, or a mixture of both.

  • New Method option within ‘Specify calculation parameters’, allowing the user more control over the ‘Main Peak Retention Time Window’ to improve main peak identification in Optical Only and Variant Analysis workflows

  • Bioprocessing workflow: Additional sample list columns for Time Point and Dilution Factor that facilitates processing time series trending data (in bioprocess monitor or in third party solutions) and dilution factor to enable clearer results visualization and trending.

Key benefits in Intact Mass 1.8 include:

  • Support for PDA optical detectors. In addition to TUV, users can now view the MaxPlot optical channel from the PDA detector, and use this channel for detection. If the injection contains PDA data, the MaxPlot chromatogram is displayed and used for peak detection. If the MaxPlot chromatogram is missing, the first optical chromatogram in the injection is displayed and used for peak detection. 
  • Support for Sample Organizer and Sample Manager vials, allowing up to19 microtiter plates, or, 9 intermediate height plates (or 2-mL vial holders), or, 6 deep-well plates (or 4-mL vial holders). Increasing the potential throughput for Intact Mass users.
  • Optical-only workflows with built in IEX, SEC and reverse-phase column support and analysis expand the utility of Intact Mass to groups within the laboratory without MS requirements. 
  • Automatic sample report generation further supports a high-throughput Intact Mass workflow. Users do not need to open complete analyses to download individual reports. They now have the option to download reports to a local folder automatically upon completion of processing, and also the option of a high-throughput report template designed to deliver the important details from a large amount of data in an efficient manner.
  • Grouped calculations allow streamlined IEX, SEC and reverse-phase analysis using MS data.
  • Processing of analyses can now be cancelled, preventing loss of time and resources processing analyses with known issues.

CONFIRM Sequence

CONFIRM Sequence

The CONFIRM Sequence application enables streamlined oligonucleotide sequence confirmation and impurity characterization workflow

Key benefits in this release include:

  • The user can now confirm if their chosen nucleic acid digestion strategies can theoretically produce the desired sequence coverage, using a visualization of theoretical digest sequence coverage, including calling out segments of isobaric mass ambiguity. This helps users to determine the best digestion strategy to achieve optimal sequence coverage using unique digestion products.
  • Localization into Japanese

Map Sequence

Map Sequence

waters_connect Map Sequence enables accurate mass mapping of digested oligonucleotides.

Versions released

waters_connect 3.6 is compatible with Map Sequence 1.0.

Key benefits in this application include:

  • Input of in silico predicted digestion products
  • Processing of pre-acquired data to identify digestion products
  • Grouped results for rapid assessment of sequence coverage
  • Identification of structural isomers and sequence repeats
  • Output of results for coverage map review

Note: full information on new features and quality improvements available in the release notes.

Applications

waters_connect for Quantitation

waters_connect for Quantitation

Quantitative analysis with tandem quadrupole mass spectrometry systems

waters_connect for Biopharma

waters_connect for Biopharma

Biopharmaceutical accurate mass applications for protein-based therapeutics, vaccines, and nucleic acid-based therapeutics.

Acquisition

  • Sample Submission 2.4.0 [new]
  • Acquisition Method Editor 3.7.0 [new]
  • UNIFI 3.12.0 [new]
  • Laboratory Network Device 1.21.0 [new] 
  • Cloud Edge software for System Monitoring 4.15

Data View & Processing

  • LC-MS Toolkit 1.15.0 [new] 
  • UNIFI 3.12.0 [new] 
  • Data Convert 2.3.0 
  • Peptide MAM 1.8.2 [new] 
  • Intact Mass 1.9.0
  • CONFIRM Sequence 1.4.0
  • MAP Sequence 1.0.0

Instrument Drivers

  • BioAccord 3.4.0
  • Xevo G2-XS QTof 4.4.0
  • Xevo G3 QTof 1.3.0
  • Xevo MRT 1.1.0
  • Vion IMS QTof 4.3.0
  • ACQUITY UPLC DP 3.7.0

waters_connect for Bioprocessing

waters_connect for Bioprocessing

Bioprocess accurate mass applications for process (spent cell culture media) and product quality attribute monitoring including the Bioprocess Walk-Up Solution.

Acquisition

  • Sample Submission 2.4.0 [new] 
  • Acquisition Method Editor 3.7.0 [new] 
  • Laboratory Network Device 1.21.0 [new] 
  • Cloud Edge software for System Monitoring 4.15

Data View & Processing

  • LC-MS Toolkit 1.15.0 [new] 
  • UNIFI 3.12.0 [new] 
  • Intact Mass 1.9.0
  • Peptide MAM 1.8.2 [new]

Instrument Drivers

  • BioAccord 3.4.0
  • ACQUITY UPLC DP 3.7.0

waters_connect for Small Molecules

waters_connect for Small Molecules

Accurate mass-based solutions for screening of small molecules with versatile qualitative and quantitative analysis of compounds like pesticides, drugs of abuse, metabolites, impurities, extractables, and leachables.

Acquisition

  • Sample Submission 2.4.0 [new] 
  • Acquisition Method Editor 3.7.0 [new] 
  • UNIFI 3.12.0 [new] 
  • Laboratory Network Device 1.21.0 [new]
  • Cloud Edge software for System Monitoring 4.15

Data View & Processing

  • LC-MS Toolkit 1.15.0 [new] 
  • UNIFI 3.12.0 [new] 
  • Data Convert 2.3.0

Instrument Drivers

  • ACQUITY RDa 3.4.0
  • Xevo G2-XS QTof 4.4.0
  • Xevo G3 QTof 1.3.0
  • Xevo MRT 1.1.0
  • Vion IMS QTof  4.3.0
  • ACQUITY UPLC DP 3.7.0

waters_connect for Omics

waters_connect for Omics

Accurate mass-based metabolomics, lipidomics and metabolite identification.

Acquisition

  • Sample Submission 2.4.0 [new] 
  • Acquisition Method Editor 3.7.0 [new] 
  • Laboratory Network Device 1.21.0 [new]
  • Cloud Edge software for System Monitoring 4.15

Data View & Processing

  • LC-MS Toolkit 1.15.0 [new] 
  • UNIFI 3.12.0 [new] 
  • Data Convert 2.3.0

Instrument Drivers

  • Xevo G2-XS QTof 4.4.0
  • Xevo G3 QTof 1.3.0
  • Xevo MRT 1.1.0
  • ACQUITY UPLC DP 3.7.0

[new] = latest application release.

Configurations

This section provides an overview on supported operating systems, maximum number of instrument systems in a Network install and ACQUITY pumps, detectors, sample managers, column compartments available in waters_connect 3.6.0.

Operating System Support for Workstation Installs

Operating System Support for Workstation Installs

Operating System
Windows

Requirements

  • Windows Defender must be set to Off
  • OS language: English (US), Japanese (Japan).
  • Windows images provided with waters_connect PCs include Windows IoT Enterprise licensing which enables extended support on the operating system end of service over the standard edition. View more information on Windows releases.

Versions Supported

Workstation PC

  • Windows 10 Enterprise LTSC 2021 edition (version 21H2)
  • Windows 10 Enterprise IoT LTSC 2021 edition (version 21H2)*
  • Windows 10 Pro version 22H2

Operating System Support for Network Installs

Operating System Support for Network Installs

Operating System
Windows

Requirements

  • Windows Defender must be set to Off
  • Server and LND OS language: English (US), Japanese (Japan) (Server and LND).
  • Client OS language: Deployment possible on European and Japanese language versions of Windows. Hub is displayed in English (US) or Japanese (Japan) only.
  • Windows images provided with waters_connect PCs include Windows IoT Enterprise licensing which enables extended support on the operating system end of service over the standard edition. View more information on Windows releases.

Versions Supported

Server PC

  • Windows Server 2019 Standard

LND PC

  • Windows 10 Enterprise LTSC 2021 edition (version 21H2)
  • Windows 10 Enterprise IoT LTSC 2021 edition (version 21H2)*
  • Windows 10 Pro version 22H2

Client PC

  • Windows 10 Enterprise LTSC 2021 edition (version 21H2)
  • Windows 10 Enterprise IoT LTSC 2021 edition (version 21H2)*
  • Windows 10 Pro version 22H2

Mass spectrometry instruments supported on a single waters_connect network deployment

Mass spectrometry instruments supported on a single waters_connect network deployment

Instrument Type

Instrument Type

Instrument Type

Instrument Type

Instrument Type

Instrument Type

Instrument

Total Number of Systems

Recommended Number of Client PCs

Recommended Number of Users

Tof

Tof

Tof

Tof

Tof

Tof

  • ACQUITY RDa
  • BioAccord LCMS system 
  • Mix of Tof

up to 6

up to 6

  • up to 6 (concurrent)
  • up to 25 (active software accounts)

QTof

QTof

QTof

QTof

QTof

QTof

  • Xevo G2-XS QTof
  • Xevo G3 QTof
  • Vion IMS QTof
  • Mix of Tof and QTof
  • (Xevo MRT not supported)

up to 4

up to 4

  • up to 4 (concurrent)
  • up to 25 (active software accounts)

Tof & QTof

Tof & QTof

Tof & QTof

Tof & QTof

Tof & QTof

Tof & QTof

  • Mix of Tof and QTof
  • (Xevo MRT not supported)

up to 4

up to 4

  • up to 4 (concurrent)
  • up to 25 (active software accounts)

TQ

TQ

TQ

TQ

TQ

TQ

  • Xevo TQ-S cronos
  • Xevo TQ-S micro
  • Xevo TQ-XS 
  • Xevo TQ Absolute
  • Mix of Quads

not supported

not supported

not supported

TQ, Tof, & QTof

TQ, Tof, & QTof

TQ, Tof, & QTof

TQ, Tof, & QTof

TQ, Tof, & QTof

TQ, Tof, & QTof

  • Mix of Quads
  • QTofs/Tofs

not supported

not supported

not supported

ACQUITY Instrument Systems (such as pumps, detectors, sample managers, column compartments) supported by waters_connect driver pack ACQUITY UPLC DP v3.7.0

ACQUITY Instrument Systems (such as pumps, detectors, sample managers, column compartments) supported by waters_connect driver pack ACQUITY UPLC DP v3.7.0

Note: ACQUITY modules firmware versions and more information are detailed in the ACQUITY UPLC drive pack release notes.


Microscale ACQUITY UPLC Systems

Microscale ACQUITY UPLC Systems

ACQUITY UPLC M-Class

ACQUITY UPLC M-Class

UPLC Configuration

  • uBinary Solvent Manager
  • uSample Manager-Fixed Loop
  • Auxillary Solvent Manager
  • Trap Valve Manager

Acquisition Apps

  • Sample Submission

Supported MS Instruments

  • Xevo MRT with NanoLockSpray and low-flow ESI probe
  • Xevo G3 QTof with NanoLockSpray and low-flow ESI probe
  • Xevo G2-XS QTof with low-flow ESI probe only

Analytical ACQUITY UPLC Systems

Analytical ACQUITY UPLC Systems

ACQUITY Premier/ACQUITY H-Class Binary Series (15,000 PSI limited systems)

ACQUITY Premier/ACQUITY H-Class Binary Series (15,000 PSI limited systems)

UPLC Configuration

  • Binary Solvent Manager (BSM)
  • Sample Manager - Flow Through Needle (SM-FTN)
  • Column Heater (CH-A)
  • Column Manager (CM-A/CM-Aux): (with S up to 2 CM-Aux units using 6 columns)

Acquisition Apps

  • Sample Submission (S)
  • UNIFI (U)

Supported MS Instruments

  • BioAccord (S & U)
  • ACQUITY RDa (U)
  • Xevo G2-XS QTof (S & U)
  • Xevo G3 QTof (S & U)
  • Vion IMS QTof (U)
  • Xevo MRT (S)

ACQUITY Premier/ACQUITY H-Class Quaternary Series (15,000 PSI limited systems)

ACQUITY Premier/ACQUITY H-Class Quaternary Series (15,000 PSI limited systems)

UPLC Configuration

  • Quaternary Solvent Manager (QSM)
  • Sample Manager - Flow Through Needle (SM-FTN)
  • Column Heater (CH-A)
  • Column Manager (CM-A/CM-Aux): (with S up to 2 CM-Aux units using 6 columns)

Acquisition Apps

  • Sample Submission (S)
  • UNIFI (U)

Supported MS Instruments

  • BioAccord (S & U)
  • ACQUITY RDa (U)
  • Xevo G2-XS QTof (S & U)
  • Xevo G3 QTof (S & U)
  • Vion IMS QTof (U)
  • Xevo MRT (S)

ACQUITY UPLC I-Class Plus Series (18,000 PSI limited systems)

ACQUITY UPLC I-Class Plus Series (18,000 PSI limited systems)

UPLC Configuration

  • Solvent Manager (BSM)
  • Sample Manager - Flow Through Needle (SM-FTN)
  • Sample Manager – Fixed Loop (SM-FL)
  • Column Heater (CH-A)
  • Column Manager (CM-A)

Acquisition Apps

  • Sample Submission (S)
  • UNIFI (U)

Supported MS Instruments

  • BioAccord (S & U)
  • ACQUITY RDa (U)
  • Xevo G2-XS QTof (S & U)
  • Xevo G3 QTof (S & U)
  • Vion IMS QTof (U)
  • Xevo MRT (S)

ACQUITY UPLC Series (15,000 PSI limited systems)

ACQUITY UPLC Series (15,000 PSI limited systems)

UPLC Configuration

  • Binary Solvent Manager (BSM)
  • Sample Manager – Fixed Loop (SM-XY)
  • Column Heater HTCH
  • Column Manager CM/CHC

Acquisition Apps

  • UNIFI

Supported MS Instruments

  • ACQUITY RDa
  • Xevo G2-XS QTof

ACQUITY UPLC Tunable UV (TUV) Detector

ACQUITY UPLC Tunable UV (TUV) Detector

Acquisition Apps

  • Sample Submission (S)
  • UNIFI (U)

Supported MS Instruments

  • BioAccord (S & U)
  • ACQUITY RDa (U)
  • Xevo G2-XS QTof (S & U)
  • Xevo G3 QTof (S & U)
  • Vion IMS QTof (U)
  • Xevo MRT (S)

ACQUITY UPLC Photodiode Array (PDA)/eLambda PDA Detector (1; 2)

ACQUITY UPLC Photodiode Array (PDA)/eLambda PDA Detector (1; 2)

Acquisition Apps

  • Sample Submission (S)
  • UNIFI (U)

Supported MS Instruments

  • BioAccord (S & U)
  • ACQUITY RDa (U)
  • Xevo G2-XS QTof (S & U)
  • Xevo G3 QTof (S & U)
  • Vion IMS QTof (U)
  • Xevo MRT (S)

ACQUITY UPLC Fluorescence (FLR) Detector

ACQUITY UPLC Fluorescence (FLR) Detector

Acquisition Apps

  • UNIFI

Supported MS Instruments

  • BioAccord
  • ACQUITY RDa
  • Xevo G2-XS QTof
  • Xevo G3 QTof
  • Vion IMS QTof

ACQUITY Common Platform Sample Organizer (CPSO)

ACQUITY Common Platform Sample Organizer (CPSO)

Acquisition Apps

  • Sample Submission (S)
  • UNIFI (U)

Supported MS Instruments

  • BioAccord (S & U)
  • ACQUITY RDa (U)
  • Xevo G2-XS QTof (S & U)
  • Xevo G3 QTof (S & U)
  • Vion IMS QTof (U)
  • Xevo MRT (S)

ACQUITY eSAT/IN Module

ACQUITY eSAT/IN Module

Acquisition Apps

  • UNIFI

Supported MS Instruments

  • BioAccord
  • ACQUITY RDa
  • Xevo G2-XS QTof
  • Xevo G3 QTof
  • Vion IMS QTof 

Supporting Files

Back To Top Back To Top